To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
about 1 year ago in OpenPlant PID 0 Future consideration

Page connectors to link in file based mode.

Currently page connectors only link from drawing to drawing while using Plantsight. We need this when using file based mode also.
over 3 years ago in OpenPlant PID 0 Future consideration

Tag Replication to display full tag

When using the tag replication tool, the main tag indicates replication by adding the number of replicated components in parenthesis. What we would like to see is for the replication tool to prompt the user to place each replicated tag annotation ...
over 1 year ago in OpenPlant PID 0 Future consideration

Enhance Valve Placement to allow users to set the valve state, actuator, and end condition properties in the placement dialog

As a piping designer, I would like to be able to set the valve state, actuator, and end conditions in the placement dialog so that I can initially set what I need and don't have to change it later by modifying the property values. Proposed Solutio...
about 1 year ago in OpenPlant PID 0 Future consideration

Valve State should work for all components

This would allow a user to have more than once cell for the same class and display the component differently. Having the PropertyBasedCells Extend Type work across the class structure, would help to avoid unnecessary classes from being created in ...
over 1 year ago in OpenPlant PID 1 Planned

Need to connect Valves directly to a nozzle without placing a pipeline

See attached picture. In general it could happen that a nozzle gets a Valve connected with a plug or a blind flange at the end. In the moment it is not possible to place the valve directly at a nozzle without drawing a pipeline.
over 3 years ago in OpenPlant PID 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 3 years ago in OpenPlant PID 0 Future consideration

Allow additional components to automatically receive properties when placed inside a panel

Currently, only instruments will inherit various properties from a panel when placed inside borders of the panel. However, there are other classes of components that would benefit from the automatic panel relationship. One in particular is a PLC (...
about 1 year ago in OpenPlant PID 3 Already exists

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
2 months ago in OpenPlant PID 0 Future consideration

Oval Instrument Parametric bubbles - Other functions

At the moment the Oval bubbles (Place Instrument Parametric) are only available as discrete instruments. Please can you extend the oval bubbles to also include the other functions like: Computer Function Distributed Digital Distributed Analog
3 months ago in OpenPlant PID 0 Future consideration