OpenPlant PID

To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
over 3 years ago in OpenPlant PID Planned

Page connectors to link in file based mode.

Currently page connectors only link from drawing to drawing while using Plantsight. We need this when using file based mode also.
almost 6 years ago in OpenPlant PID Future consideration

Allow all sub-instrument class components acquire panel properties during placement

Currently, only INSTRUMENT_PARAMETRIC class and it's sub-classes will work with PANEL class to acquire panel properties during instrument placement. Defining I/O POINTS in the schema as a sub-class of instruments, and placing them from a cell libr...
3 months ago in OpenPlant PID Future consideration

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
over 2 years ago in OpenPlant PID Future consideration

Valve State should work for all components

This would allow a user to have more than once cell for the same class and display the component differently. Having the PropertyBasedCells Extend Type work across the class structure, would help to avoid unnecessary classes from being created in ...
over 3 years ago in OpenPlant PID Planned

Tag Replication to display full tag

When using the tag replication tool, the main tag indicates replication by adding the number of replicated components in parenthesis. What we would like to see is for the replication tool to prompt the user to place each replicated tag annotation ...
over 3 years ago in OpenPlant PID Future consideration

Enhance Valve Placement to allow users to set the valve state, actuator, and end condition properties in the placement dialog

As a piping designer, I would like to be able to set the valve state, actuator, and end conditions in the placement dialog so that I can initially set what I need and don't have to change it later by modifying the property values. Proposed Solutio...
over 3 years ago in OpenPlant PID Future consideration

Need to connect Valves directly to a nozzle without placing a pipeline

See attached picture. In general it could happen that a nozzle gets a Valve connected with a plug or a blind flange at the end. In the moment it is not possible to place the valve directly at a nozzle without drawing a pipeline.
over 5 years ago in OpenPlant PID Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
almost 6 years ago in OpenPlant PID Future consideration

PlantSight version Comparison in OPPID

Hi Please can we have a version comparison of OPPIDs in PlantSight similar to the version comparison in OPM
over 2 years ago in OpenPlant PID Future consideration