Ensuring Custom information header in reference does not disappear when published to Imodel

Dear Project Admin, our custom project information header disappear whenever we publish to imodel. This information can be found in the nested reference files of our main container file. When we are giving to our client the main container model, t...
4 months ago in OpenPlant Modeler 1 Future consideration

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc.

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc. Similar to end condition mappings End Condition Extend Type for valves.
9 months ago in OpenPlant PID 0 Future consideration

LUG JOINT type calculation to add in OPM

LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE. Logging on behalf of E365 user - Stantec Consulting - Australia
almost 2 years ago in OpenPlant Modeler 2 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
9 months ago in OpenPlant Modeler 0 Future consideration

Import attributes from Excel

We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
about 1 year ago in OpenPlant Modeler 1 Future consideration

Ability to import PCF files

OpenPlant Modeler users would benefit from .PCF import when there is a need to import models from other Plant Design software. This import process could, at first, bring basic routing and piping accessories, letting users select which OpenPlant sp...
about 4 years ago in OpenPlant Modeler 1 Will not implement

OPIM need to read correctly ProjectWise folders

OPIM must read dms folders directly. Do not create subfolders like: C:\PW_ADMIN_WD\dms02651\styles\IFC\config and C:\PW_ADMIN_WD\dms01754\Workspaces\WorkSpace\Worksets\OpenPlantMetric\Standards\OpenPlant\Isometrics\styles\IFC\config This gives man...
about 4 years ago in OpenPlant Isometrics Manager 2 Planned

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
9 months ago in OpenPlant Modeler 0 Future consideration

Pass new COG from model to Iso

COG is important for a spools created from Iso drawings. Knowing where the COG is on each spool makes lifting and field assembly easier and safer.
over 2 years ago in OpenPlant Modeler 0 Future consideration

Create an Advanced Query Function that can pull Class UOM

Create an ECSQL built-in function like ‘ec_clanname() and ‘ec_classid()’. It could have this form: ec_getPropertyUnit( ecclass, ecproperty ) Its functionality is to pull the component's unit of measurement (UOM).
9 months ago in OpenPlant Engineering Data Manager 0 Future consideration