Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
12 months ago in OpenPlant PID 0 Future consideration

Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
12 months ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
12 months ago in OpenPlant PID 0 Future consideration

Would like a Progress Message displayed during PlantSight synchronization

Whenever you push drawing records to PlantSight, it will prompt you with the Difference Dialog. Once we click on Sync it took time to reflect the dialog for "Please enter comments" but during that phase (difference dialog to comment dialog) there ...
12 months ago in OpenPlant PID 0 Future consideration

Allow Multiple selection for changing pipeline type

Currently the pipeline type can be changed for only one pipeline at a time because it does not allow multiple selection. It would be nice if we had the ability to change the pipeline type for multiple pipelines in one go.
about 1 year ago in OpenPlant PID 0 Future consideration

Merge Pipe Runs tool should merge non colinear segments

Currently in OPPID the Merge Pipe Runs tool only merges colinear segments. See attached video of how you need to workaround the limitation. It would be helpful if the Merge Pipe Runs tool could merge non-colinear segments as well. By enhancing thi...
about 1 year ago in OpenPlant PID 0 Future consideration

Add a key-in to remove an Associated Item value (SYSTEM)

In some situations, I may wish to remove an associated item property (i.e. SYSTEM) from existing components and documents. For example, I may want to reuse existing documents for a new project that has a different tagging convention and doesn't ne...
about 1 year ago in OpenPlant PID 0 Future consideration

Place Existing Signal Page Connector include column for connected instrument line type

Place Existing Signal Page Connector should include a column for connected instrument line type. If there were multiple Signal Page Connectors available, it is currently impossible to distinguish between pneumatic, capillary, electrical, etc. Sinc...
about 1 year ago in OpenPlant PID 0 Future consideration

Automatically reposition flow arrows to avoid overlapping inline components

In situations where the flow arrow overlaps a component on the pipeline it would be nice if the software would automatically reposition the flow arrow to avoid the overlap if possible. If there is insufficient space to display the flow arrow it wo...
about 1 year ago in OpenPlant PID 0 Future consideration

Ability to Have two Instrument Parametric Annotation With Bubble

In some cases, an instrument device has two different Performance styles (local panel and Distributed Control System). This means we need to be able to place two Instrument Parametrics (bubbles) with the same code.
about 1 year ago in OpenPlant PID 0 Future consideration