Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 119

Allow offset for valve operators

We often have valves where the operators do not sit in the center of the valve body. We need the ability with in the specs to account for that offset and to be properly represented in the model. Currently only gearbox operators allow for this offs...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Export with properties

Currently when exporting an IFC model from OpenPlant Modeler, many of the properties aren't exported. Please add an option that the IFC model will include all the data from the OPM model. This is very helpful for exporting to a 3rd party software....
5 months ago in OpenPlant Modeler 3 Already exists

Supports placement on Fittings, tees, elbows etc. and supports customization as primary and secondary.

At present we cannot place U-bolts or support locators on fittings, elbow and tees as a result in Isometric we need to add these supports manually and get it counted in the BOM. We need more options to create customized supports as primary and sec...
about 3 years ago in OpenPlant Modeler 1 Planned

Assembly Manager in OPM

Users would be able to place multiple OPM-components in one go by creating a user defined component library, with retaining individual properties per component. Todays´ capabilities don´t hold individual properties (place custom component from cel...
almost 3 years ago in OpenPlant Modeler 1 Future consideration

Match Properties of Pipeline

Please can you bring back a tool similar to the old function that existed in PlantSpace Design where you could select a pipe and by pressing a button it would match the pipeline number, system, service plant area, unit number, size, specifciation ...
over 1 year ago in OpenPlant Modeler 1 Future consideration

Validation of Component Dimensions

OPM users need a way to check dimensions of components against the pipespecs. We have had several instances where pipespec dimensions get updated by piping engineering after OPM Users have already routed in the model. OPM users currently have no w...
almost 3 years ago in OpenPlant Modeler 0 Future consideration

Ability to auto perform connectivity check

If Openplant can detect and connectivity error and display it as an error to the user, it should be able to automatically run connectivity check. At the very least, "Run Connectivity Check" should be added as a button to the disconnect error dialo...
3 months ago in OpenPlant Modeler 0 Future consideration

True Beta Testing

I would really like to see a true beta testing program implemented for OpenPlant. I have logged 40+ product defects after upgrading to newer versions of OPM. I am still waiting on fixes from the past years, and my users are struggling with in prod...
7 months ago in OpenPlant Modeler 0 Future consideration

Fix and Enhance the Details(Items) Dialog so it's usable.

Currently the Details (Items) dialog will show a list of what ever has been selected. Option to sort dialog, defaults back 'Item' when working on data past the first page of data, (scroll down past the first 20 lines say) When a number of items ar...
7 months ago in OpenPlant Modeler 1 Future consideration

Wafer Bolt - Two bolts in the spec with the same nominal diameter and BOLT_LEN but different Description, OPM picks the first spec entry.

OpenPlant Modeler’s working behavior is to pull the nearest bolt entry from spec with a lower BOLT_LEN compared to the calculated length if there’s no available bolt entry from spec with a BOLT_LEN that is either equal or greater than the calculat...
over 1 year ago in OpenPlant Modeler 0 Future consideration