Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 119

Spec Grid Record for Operators Upon Valve Placement in OpenPlant Modeler

In OpenPlant Modeler, we have only one option to place valve, meaning we dont have valve with Open and Closed type for its placement. As per standard, for open and closed type of valve we have different operator length. At present in OpenPlant Mod...
9 months ago in OpenPlant Modeler 0 Future consideration

Better Graphics for Tappings

Please can you improve the graphics of tappings/unreinforced and reinforced branches to be more graphically correct. At the moment, especially on large pipe sizes where connections are not tee in, the graphics of the connecting pipe stop short of ...
over 1 year ago in OpenPlant Modeler 2 Future consideration

Enable the Change Text Attributes

It makes it easier to change the text attributes, it's enabled in Microstation.
9 months ago in OpenPlant Modeler 0 Future consideration

Ability to Delete Component along with Tag in Plantsight from OPM directly

In an instance Component was placed in OPM and was pushed to Plantsight.We were not able to checkout the component through any associated item as it was not reflected in PlantSight explorer tab.If we verify it is only into Physical Properties not ...
9 months ago in OpenPlant Modeler 1 Will not implement

Add schedule report to OPM

I would like to suggest an addition to Open Plant Modeler functionality, similar to Open Building Design. That is an option to create a schedule report, containing component attributes with the option to alter, apply and save them. Changes also ap...
about 3 years ago in OpenPlant Modeler 0 Future consideration

Jacket Line Routing & Jacketed iso drawing

Currently, we are not able to route jacket pipe on the primary process pipe, and that's why iso drawings also do not get generated with jacketed line. Due to the feature is not available in Bentley, all these works like jacket MTC, and Iso drawing...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Nozzle Manager - Enable property DEVICE_TYPE_CODE to define Unique NOZZLE tag along with NUMBER.

Currently a Nozzle in Nozzle Manager is defined by the NUMBER field. When using PlantSight/OPPID/OPM, the Number needs to be defined as a Number - Not N1 or M1 (Nozzle or Manhole). Tagging of a nozzle is generally defined as EQP_NO-DEVICE_TYPE_COD...
10 months ago in OpenPlant Modeler 0 Future consideration

Reprojection of OpenPlant Models to Align to GCS

Other Bentley design tools (OBD) permit the modeling of content at the X=0, Y=0, and orientation in the X axis. When the GCS system is added to the file, and aligned to the modeled content, and the model is published to PlantSight, the components ...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Cutback 180 degree elbow in AutoFitting

Can we get the ability to do cut back 180 degree returns (elbows) in the AutoFitting settings when place pipe and using the Standard Elbow option. Currently you have to use the Pipe Bend option which requires the designers look up the radii of eac...
over 1 year ago in OpenPlant Modeler 3 Future consideration

Weight conversion from imperial units to metric units for pipe spools

Story Narrative- A specification is created in imperial units, and when one wants to use it in metric workset the numeric value of the weights is not being converted for the pipe spools. However, the numeric value of the weights is being converted...
almost 2 years ago in OpenPlant Modeler 1 Future consideration