I am logging this Idea on behalf of User. Below are the details.
SR-7001518531
Case Number-CS0071599
Account-Mitsubishi Heavy Industries
Contact-Miwako Hayasaki (miwako.hayasaki.mw@mhi.com )
User has also logged a BUG regarding this issue. Below are the BUG list for the reference.
Help Ticket 1171672: Repeating angle symbol on the same angle one pipe unintentionally
Service Case 1267788: [CS0071599] Control the repetition of slope symbol
Problem Description: The users would like to manage the slope symbol quantity in the same angle's pipe. The symbols locate on each point currently. But they don't need multiple symbols in the same angle's pipe. The previous version does not locate the multiple symbols in it. Please find an attached file for it.
AutoPipe Version: 12.08.04.09
Steps:
Change the style.xml description from "NONE" to "ANGLE" in the SLOPE block.
C:\ProgramData\Bentley\AutoPIPE 2023\isoextractor\projects\project01\stress\Config\style.xml
Launch AutoPIPE and open Walkthru
Extend run from A10 like below
Run the analysis
Save the stress iso.
How frequently will feature be used? | Several times a day |
How much time will you save? | This will reduce user's Editing time by 5 min per isosheet. |
Your Industry | Energy Infrastructure |