Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant PID

Showing 48

To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
over 1 year ago in OpenPlant PID 0 Planned

PlantSight version Comparison in OPPID

Hi Please can we have a version comparison of OPPIDs in PlantSight similar to the version comparison in OPM
8 months ago in OpenPlant PID 0 Future consideration

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
9 months ago in OpenPlant PID 0 Future consideration

Oval Instrument Parametric bubbles - Other functions

At the moment the Oval bubbles (Place Instrument Parametric) are only available as discrete instruments. Please can you extend the oval bubbles to also include the other functions like: Computer Function Distributed Digital Distributed Analog
10 months ago in OpenPlant PID 0 Future consideration

Tag Replication to display full tag

When using the tag replication tool, the main tag indicates replication by adding the number of replicated components in parenthesis. What we would like to see is for the replication tool to prompt the user to place each replicated tag annotation ...
almost 2 years ago in OpenPlant PID 0 Future consideration

Enhance Valve Placement to allow users to set the valve state, actuator, and end condition properties in the placement dialog

As a piping designer, I would like to be able to set the valve state, actuator, and end conditions in the placement dialog so that I can initially set what I need and don't have to change it later by modifying the property values. Proposed Solutio...
over 1 year ago in OpenPlant PID 0 Future consideration

Valve State should work for all components

This would allow a user to have more than once cell for the same class and display the component differently. Having the PropertyBasedCells Extend Type work across the class structure, would help to avoid unnecessary classes from being created in ...
almost 2 years ago in OpenPlant PID 1 Planned

Page connectors to link in file based mode.

Currently page connectors only link from drawing to drawing while using Plantsight. We need this when using file based mode also.
about 4 years ago in OpenPlant PID 0 Future consideration

Populating data from spec fields to Pipe property

The PID does not support the feature of populating data from pipe spec fields to Pipe property. At current stage it is only possible for valves.
8 months ago in OpenPlant PID 0 Future consideration

Allow additional components to automatically receive properties when placed inside a panel

Currently, only instruments will inherit various properties from a panel when placed inside borders of the panel. However, there are other classes of components that would benefit from the automatic panel relationship. One in particular is a PLC (...
almost 2 years ago in OpenPlant PID 3 Already exists