Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Raceway and Cable Management

Showing 103

Add dimensions to 2D extraction graphics

I got multiple requests (ENEL, Iraq Oil, Grupotec) to add the dimensions (e.g. distance of conduit to side of concrete and distance between conduits) automaticaly like it work for the size of concrete.
over 4 years ago in Bentley Raceway and Cable Management 0 Future consideration

Additional cable laying method related to cable size

A user like to use an additional cable laying method related to the cable size. That mean cable with a specified diameter shall be routed single layer and all cable smaller shall be routed multi layer, also the two laying methods shall be separate...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Property Field of length for Fittings

Would like a property to be added to fittings that get populated with the length of the fitting when the part is inserted in the drawing. This will be useful in checking the overall length of a given raceway ID. The Raceway Schedule BOM report is ...
over 1 year ago in Bentley Raceway and Cable Management 2 Future consideration

Raceway Label with a box around the label

I saw multiple request to add a box around the Raceway Label.
about 3 years ago in Bentley Raceway and Cable Management 0 Future consideration

Duct Bank Concrete Tool should allow me to save and reuse configurations

It would be nice to be able to save and reuse Duct Bank Concrete configurations so that I can quickly change the concrete settings based on commonly used configurations.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Show Raceway type in Raceway Fill Info

It will be useful to show not only the size of raceway in Raceway Fill Info dialog. It shall also show the raceway type, e.g. Cable Tray, Cable Ladder, etc as additional info.
over 3 years ago in Bentley Raceway and Cable Management 0 Future consideration

Show raceway ID in Raceway Fill Info

It shall show the raceway ID as additional entry in the Raceway Fill Info dialog
over 3 years ago in Bentley Raceway and Cable Management 0 Future consideration

Would like to include UDAs in section cuts

It would be helpful to have the ability to add raceway and equipment UDAs into section cut tables as shown in the attached file.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to specify different length ,width ,height values for supports in Trench

It would be helpful if we could apply different length, width, and height values for supports of different voltage levels in the Trench Router. Today you can only specify one size for all voltage levels.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Trench Cover on separate level

It would be nice if the level that the trench cover was placed on was configurable in the CAD Settings dialog so that it could be turned on/off.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration