Flip Dimension Tool

When the dimensioning is unreadable. This tool allows the user to flip the dimension to 90° planes.This makes the drawing more readable
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Valve State should work for all components

This would allow a user to have more than once cell for the same class and display the component differently. Having the PropertyBasedCells Extend Type work across the class structure, would help to avoid unnecessary classes from being created in ...
over 1 year ago in OpenPlant PID 1 Planned

Need to connect Valves directly to a nozzle without placing a pipeline

See attached picture. In general it could happen that a nozzle gets a Valve connected with a plug or a blind flange at the end. In the moment it is not possible to place the valve directly at a nozzle without drawing a pipeline.
over 3 years ago in OpenPlant PID 0 Future consideration

Version Comparison for Queries / Lists / Reports

Current version comparison is a nice feature. It shows visually in context of 3D view what has changed between Named Versions. However, the real value add would be to actually show the changes in list form. (or queries) - Currently i am not able t...
over 3 years ago in OpenPlant Engineering Data Manager 1 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 3 years ago in OpenPlant PID 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 3 years ago in OpenPlant Engineering Data Manager 2 Will not implement

Have PID viewer available in Consistency manager

In file based workflow with PID to 3d, the i-model is attached so the user can see the PID against what they are modeling. We need this same viewing capability while using PlantSight with consistency manager.
over 3 years ago in OpenPlant Modeler 0 Future consideration

MixMetric should have ProStructures and BRCM

We are trying use BRCM and Prostructures module in OpenPlant Modeler. We can see that there is an option to enable the module in OpenPlant Project Administrator for Metric and Imperial projects but we do not see that in the MixMetric projects. Kin...
about 1 month ago in OpenPlant Modeler 0 Needs review

Allow offset for valve operators

We often have valves where the operators do not sit in the center of the valve body. We need the ability with in the specs to account for that offset and to be properly represented in the model. Currently only gearbox operators allow for this offs...
6 months ago in OpenPlant Modeler 0 Future consideration

Enable direct reporting capability from PlantSight EDM.

Enable reporting output to PDF with ability to format, customize, compile/bind and save project settings.
about 1 year ago in OpenPlant Engineering Data Manager 0 Future consideration