Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Raceway and Cable Management

Showing 115

Adding or removing fittings should minimize the number of non-standard length straight sections

It would be helpful if the software would optimize the way it breaks or joins straight raceway segments when fittings are inserted or deleted in order to minimize the number of non-standard length straight sections. See attached file for more info...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Need ability to define base height for design files

It should be possible, to define a base height in a design file for a building level, to use alternative relative elevation values for raceway and equipment placement and to document labels.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Improve Visualization of routing failures

Provide additional information when a route fails due to an overfilled raceway. An option to zoom to or visualize the problem area or provide the raceway ID would help to troubleshoot more quickly.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Would like to have the ability to change an existing raceway route in the Cable Manager

Would like to have the ability to change an existing raceway route in the Cable Manager for these cases: When it's necessary to add an additional raceway part in an existing route When you need to delete a number of existing parts and use other ra...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to exclude some cable types from certain raceways

Would like to have the ability to exclude some cable types from certain raceways so that there is capacity for the right set of cables to be routed through the raceways. Proposed Implementation Add a property to the Raceway Router dialog and Racew...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

New 3D cable visualization overwrite based on the Cable Status

Would like to have a different visualization in 3D cable if there is a different cable Status so that we can more easily view the phases of construction. In the current version it´s not possible to have the Status set in the Cable Manager in the 3...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Switch to turn on/off the Refresh Routing Model command

When working with a large model and needing to route large groups of cables in succession it would be nice to be able to turn off the automatic refresh of the routing model so that it's possible to manually route cables and not have to wait for th...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to filter cables in Cable Manager according to a specific Raceway Segment ID

Would like the ability to add the Raceway Segment ID as a column in the Cable Manager and filter on this field to only display cables that were routed through this Raceway segment.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to search/select tray based on tray properties

We need the ability to Query Trays – ability to search/select tray based on tray properties (voltage level, tray number, tray material, tray with cover, etc.) Right now filter in cable manager can be used to search for some raceway properties but ...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to visualize the routing model by applying routing filters

Would like the ability in the Cable Manager to visualize the routing model filtered on the defined routing filters to only display specific voltage levels like CTRL for example so that I can more easily focus on the information I am interested in.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration