Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
Status Future consideration
Workspace OpenPlant Modeler
Created by Guest
Created on Feb 17, 2022

Validation of Component Dimensions

OPM users need a way to check dimensions of components against the pipespecs. We have had several instances where pipespec dimensions get updated by piping engineering after OPM Users have already routed in the model. OPM users currently have no way to validate that the components already placed match the pipe spec or if they need to be updated. Currently the validation tools are only safe to use on non dimensional properties. If we add a dimensional property to “OPM_SPECVALIDATION_ATTRIBUTESTOCHECK” validation will update the value without actually redrawing the component resulting in significant data issues. Major dimensional info we would want to check include, Length, flange thickness, socket depth, length to main end, length to run end.

How frequently will feature be used? Once a week
How much time will you save? several man-days of checking time or addressing fabricator questions per project.
Your Industry Oil & Gas