BRCM 2024: Equipment Terminal (Target) ID Not Updating for Unopened Equipment Files During Auto Routing Import

HI, We are facing a workflow limitation in BRCM 2024 during the Auto Routing process. When importing the Cable List and Equipment List, the system updates the database and the Equipment Terminal (Target) IDs are assigned only to the equipment CAD ...
5 days ago in Bentley Raceway and Cable Management 1 Future consideration

Direct .ifc export option from BRCM

Hi, there should be a direct .ifc option from BRCM so that its handy for the user to optimise the workflow by eliminating iTwin. Also the category mapping should be possible from BRCM to Revit so that cable trays, cable ladders can be mapped with ...
19 days ago in Bentley Raceway and Cable Management 1 Future consideration

Color Coding of Raceway Configuration Grid

It would be greatly beneficial to color code the Raceway Configuration grid in Raceway Router and Duct Bank Router to show the voltage level in the grid of the layout. This would make it much easier for user to confirm their layout is done correctly.
3 months ago in Bentley Raceway and Cable Management 1 Future consideration

Adding Cable Laying Method drop down to Check Routing Connectivity Tool

While using the Check Routing Connectivity Tool, it would be highly beneficial to include an option to select the Cable Laying Method alongside voltage levels as routing filter. Currently, the tool shows connectivity based solely on voltage levels...
4 months ago in Bentley Raceway and Cable Management 0 Future consideration

Remove 31-Character Limit for Cable Names in Cable Pull Card Export

When exporting Cable Pull Cards from Cable Manager for cable names exceeding 31 characters, the process fails with the following error. Bentley.RCM.Application: An external component has thrown an exception.A corrupted Excel file is created in the...
about 1 month ago in Bentley Raceway and Cable Management 1 Will not implement

Add Manhole, Handholes, Pullboxes IDs to Cable Routing instead of Airgap

It would be extremely important to add Add Manhole, Handholes, Pullboxes IDs to Cable Routing instead of Airgap. Currently Airgap is added into the routing and this does not give design or construction team information on where the circuit should ...
5 months ago in Bentley Raceway and Cable Management 2 Future consideration

Equipment Import from Excel - rotation

Hello, I would like to suggest a new improvement for equipment import from an Excel spreadsheet. Beside equipment name, I would like also to define rotation axis and rotation degree. It will be very helpful e.g. while I am importing lighting fixtu...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Add Connector to each Object of Multi-Object Equipment for Cable Routing.

BRCM gives the user the ability to add multiple Object to an equipment before placement but only allow one connection point. This mean that routing of cable cannot be connected to the exact object of the multi-object equipment. An MCC for example ...
6 months ago in Bentley Raceway and Cable Management 0 Future consideration

Increase number of tray dividers

 Currently BRCM is limited to 3 dividers, and we have had requests for more to accommodate separation requirements.
9 months ago in Bentley Raceway and Cable Management 0 Future consideration

Raceway covers

Currently in BRCM are two settings related to covers. One is located in properties of the raceway, in UDAs as "Cover Type". It's needed to use it to include covers in BOQ. Second setting is hidden in the fitting catalogue definition per raceway ty...