It would be nice if crossing a pipeline over itself would create a jumper.

I would like the software to show a jumper when I cross a pipeline over the top of itself like it does when you have two different pipelines so that it's clear that there is not an actual joint of the pipes at that point. See attached image.
about 1 year ago in OpenPlant PID 0 Future consideration

Autofitting Filter property and SpecGrid selection

We can define this variable OPM_CUSTOM_AUTO_FIT_FILTER_PROPS = SCHEDULE to force autofitting to query elbow based on following pipe property (ex: SCHEDULE). But if we add this variable OPM_AUTOFITTING_SELECTION_GRID_FOR_ELBOW = 1 During placement ...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

AutoGenerate Spool IDs to skip Existing component state

Skipping components set to Existing, For Demolition or Vendor component states would be very useful because these components often don't form part of the fabrication. This needs to be an option, toggle, because sometimes when you are modelling the...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Standard Set of Useful Pipe Supports

It would be great if we could get a standard set of pipe supports that would allow us to change steel section. Things like 'T' posts, support trees, 'L' supports both above and below floor.
about 3 years ago in OpenPlant Modeler 1 Future consideration

Enforceable, Spec drive for P&ID

Add the ability to enfor spec drive in P&ID, or at minmum the ability to live warn a user that they are placing items that are not found in the active spec, or are not from the same spec as the line the component is being placed on.
8 months ago in OpenPlant PID 0 Future consideration

Enable word wrap for component annotation

When a long description is needed to annotate a component such as a valve I have to manually input a '\n' to force some of the text to a second line. It would be nice if there was a way to specify a boundary or character length after which the sof...
about 1 year ago in OpenPlant PID 0 Future consideration

Generated "ISOSHEETS" in piping files be carried over to next file

When we create "ISOSHEETS" for pipelines in a design file and then try to copy all contents of this file into another file / new file (i.e reference in the file > select all content > Copy > Paste into new file > Detach the reference),...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Add support to connect duct bank to manholes in a referenced DGN file

Currently, BRCM does not support duct bank connections to manholes that are referenced in from another Underground file. It's very common to have multiple underground files in a project, and manholes need to support connections to these duct banks...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Need to connect Valves directly to a nozzle without placing a pipeline

See attached picture. In general it could happen that a nozzle gets a Valve connected with a plug or a blind flange at the end. In the moment it is not possible to place the valve directly at a nozzle without drawing a pipeline.
almost 4 years ago in OpenPlant PID 0 Future consideration

Display Rules

Please can the display rules work on higher parent classes like PIPING_NETWORK_SYSTEM (Pipeline) and PIPE_COMPONENT or ISO_SHEET. The idea is to write a rule to highlight all components in a pipeline where a specific criteria is met.
over 1 year ago in OpenPlant Modeler 0 Future consideration