OpenPlant PID

Showing 44

Enforceable, Spec drive for P&ID

Add the ability to enfor spec drive in P&ID, or at minmum the ability to live warn a user that they are placing items that are not found in the active spec, or are not from the same spec as the line the component is being placed on.
5 months ago in OpenPlant PID 0 Future consideration

Would like ability to rename the category labels in the Standard Preferences dialog

It would be helpful if we had the ability to rename the category labels in the Standard Preferences dialog as highlighted in the attached screen capture.
11 months ago in OpenPlant PID 0 Future consideration

Property Category to be Defined on the Property

Currently, when adding a property or editing an existing property, the category in which the property is to reside, is defined in a separate Custom Attribute. If a user manually adds this custom attribute, it is possible to type in an incorrect na...
6 months ago in OpenPlant PID 0 Future consideration

It would be nice if crossing a pipeline over itself would create a jumper.

I would like the software to show a jumper when I cross a pipeline over the top of itself like it does when you have two different pipelines so that it's clear that there is not an actual joint of the pipes at that point. See attached image.
12 months ago in OpenPlant PID 0 Future consideration

Enable word wrap for component annotation

When a long description is needed to annotate a component such as a valve I have to manually input a '\n' to force some of the text to a second line. It would be nice if there was a way to specify a boundary or character length after which the sof...
about 1 year ago in OpenPlant PID 0 Future consideration

Need to connect Valves directly to a nozzle without placing a pipeline

See attached picture. In general it could happen that a nozzle gets a Valve connected with a plug or a blind flange at the end. In the moment it is not possible to place the valve directly at a nozzle without drawing a pipeline.
over 3 years ago in OpenPlant PID 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
almost 4 years ago in OpenPlant PID 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
over 1 year ago in OpenPlant PID 0 Future consideration

Ability to have Driver as a parametric cell upon Placement

We can place driver on an Equipment as shown in attached image, but the only possible stretch is vertically or horizontally and you cannot add vertices to the line coming off the driver to adjust that length.
11 months ago in OpenPlant PID 0 Future consideration

Update Reports to include Component Reference to PID Drawing

We would like to have the PID Drawing Number of where components are located in the following standard reports (like we already do with the process line list) so that it's easy to locate which drawings they are found in: Equipment Report Instrumen...
11 months ago in OpenPlant PID 0 Future consideration