Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Bentley Raceway and Cable Management

Showing 110 of 329

Raceway Properties should support the same UDA list selection as found in the Raceway Router

Would like to have the same UDA pick list available in the Raceway Generator dialog that is available in the Raceway Router to select a UDA list name that presets a number of UDA values so that the raceways can be generated with the proper UDA val...
12 months ago in Bentley Raceway and Cable Management 0 Future consideration

Raceway Generator should allow users to select a saved UDA list like the Raceway Router dialog

Would like to have the same UDA pick list available in the Raceway Generator dialog that is available in the Raceway Router to select a UDA list name that presets a number of UDA values so that the raceways can be generated with the proper UDA val...
12 months ago in Bentley Raceway and Cable Management 0 Future consideration

Avoid raceway overfill in manual routing

Would like the option of having the software check raceway fills when manually routing cables through raceway systems in the Cable Manager and alert the user if the fill will be exceeded.
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Perform raceway size calculation using all possible routed cable

It would be helpful if the software had an option to route all cables ignoring fill and then recommend a raceway size to accommodate the required number of cables.
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Would like a multiplier for routed cable lengths

Would like to be able to specify a multiplier that would affect the length calculation of routed cables. For example, specify that cables should be 110% of the length calculated with current methods. It may be necessary to do this on a per voltage...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Would like a new cable laying method to support Bolt Clamps.

Need a way of routing cables and supporting them with bolt clamps that can be visualized with the 3D cables running through the clamps. This kind of cable laying method is needed for ladders and c profile rails. It should deliver also the number a...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Would like raceway and equipment tags to support Plant Breakdown Structures like KKS

It would be helpful if raceway and equipment tags could be comprised of multiple properties like the Plant Breakdown Structure in OpenPlant to support these types of tagging conventions including KKS.
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Automatic Cable Routing should allow us to exclude particular raceway segments for selected cables

When the Automatic Cable Routing routine prioritizes finding the shortest path it may not choose the preferred cable routes to make installation easier. Some examples might include: Laying cables in a cable ladder is easier to install than to feed...
8 months ago in Bentley Raceway and Cable Management 0 Future consideration

Area related Raceway and Cable weight calculation

Idea from Fluor Canada related to raceway and cable weight calculations: Weight calculation related to area or CWP (construction work package) 1) Straights (parts weight in kg/m): Total Straights weight = Total straights length (m) per area or CWP...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Change Raceway ID in tag

It will be useful to enable the direct edit of raceway IDs in the file, e.g. using the Edit Text command as it work in the Equipment ID and to save this information to the raceways and update in the Raceway IDs dialog.
over 3 years ago in Bentley Raceway and Cable Management 0 Future consideration