Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Isometrics Manager

Showing 31 of 310

Create same component on multiple iso sheets

Currently we create Stress/system isometrics which contain multiple lines numbers on them. The issue is when we go to create fabrication isometrics, the components have already been assigned to the stress iso so you cant create another isosheet fo...
about 1 year ago in OpenPlant Isometrics Manager 1 Will not implement

Fix graphics on 3 elbows connected to each other.

Fix graphics on 3 elbows connected to each other. In the attached image, the proper display of the 3 elbows on the iso extracted from Plant Space Design Series. The other iso image extracted using OPIM shows the 3 elbows forming that looks like a ...
about 1 year ago in OpenPlant Isometrics Manager 1 Will not implement

Query data from iTwin and include in isometric drawing

We can use DB_QUERY to populate titleblock information from line lists that are stored in Excel or relational database. It would be nice to be able to use iTwin as a source and query these properties directly from iTwin with ECSQL as we are moving...
about 2 years ago in OpenPlant Isometrics Manager 1 Future consideration

Repeating angle symbol on the same angle one pipe unintentionally

I am logging this Idea on behalf of User. Below are the details. SR-7001518531Case Number-CS0071599Account-Mitsubishi Heavy Industries Contact-Miwako Hayasaki (miwako.hayasaki.mw@mhi.com ) User has also logged a BUG regarding this issue. Below are...
9 months ago in OpenPlant Isometrics Manager 0 Future consideration

Bentley IMS Authentication

Users are required to enter hostname:datasource for Bentley IMS login to work. Specifically, if the Datasource Name and Display Name are not the same. This is not an issue for all other Bentley products, but OPIM requires users to manually add the...
11 months ago in OpenPlant Isometrics Manager 0 Future consideration

Slope Call outs: Do not place Multiple Labels on the iso

No description provided
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Be able to create EHT (Electrical Heat Trace) Isometrics from OpenPlant

The drafters would make a copy of piping isometric line work, scale them to fit the EHT isometric title block, and then manually add the EHT layout/Power connection/RTD location. The EHT isometric may span across multiple piping isometrics and lin...
about 1 year ago in OpenPlant Isometrics Manager 3 Future consideration

Y-Strainer: Show Orientation of Branch (Blow Off / Drain)

Y-Strainer: Show Orientation of Branch (Blow Off / Drain). Please see attached image.
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Y-Strainer: Dimension to intersection of Main Line and Branch Point

Y-Strainer: Dimension to intersection of Main Line and Branch. Consider the properties, DESIGN_LENGTH_CENTER_TO_OUTLET_END + DESIGN_LENGTH_CENTER_TO_RUN_END = LENGTH
about 1 year ago in OpenPlant Isometrics Manager 0 Needs review

Create Muti-Iso sheet without breaking pipe

In the scenario where you have a Header pipe with many branches from the header pipe, the isometric becomes cluttered and unclear. In order to place an isometric break point, you need to physically break the pipe. This creates confusion for a fabr...
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration