Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 277

Structure and Column Grid Management updates

Structure and Column Grid Management updates OpenPlant Modeler and BRCM need a consistent and easy to use Structure and Column Grid Manager that users can work with to get quick reference points while locating equipment and routing piping. Ideally...
over 1 year ago in OpenPlant Modeler 1 Future consideration

Need FROM/TO for PIPING_NETWORK_SYSTEM

Hi, Currently it's only possible to get FROMs/TOs for PIPING_NETWORK_SEGMENT. It's a very important part of our engineering process/workflow to have from FROMs/TOs for a whole line (PIPING_NETWORK_SYSTEM). FROM/TO for a line can one of the followi...
5 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Concatenating the multiple User defined attributes to form separate Tag format

looking for Combined Properties Tags in BRCM, on basis of properties which can be having different kind of values, which can be selected from Picklist, drop down menu and different options
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

PlantSight version Comparison in OPPID

Hi Please can we have a version comparison of OPPIDs in PlantSight similar to the version comparison in OPM
4 months ago in OpenPlant PID 0 Future consideration

Populating data from spec fields to Pipe property

The PID does not support the feature of populating data from pipe spec fields to Pipe property. At current stage it is only possible for valves.
4 months ago in OpenPlant PID 0 Future consideration

Allow offset for valve operators

We often have valves where the operators do not sit in the center of the valve body. We need the ability with in the specs to account for that offset and to be properly represented in the model. Currently only gearbox operators allow for this offs...
9 months ago in OpenPlant Modeler 0 Future consideration

Coordinates Labelling Tool

The client wants coordinates add components which aren't generated by OPIM.This tool will create the box coordinates at the component the user chooses.Now it's not possible, we need to manually calculate the coordinates and place it manually.
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Provide Include Raceway Segments option in Cable Manager

Would be helpful to allow the user to select raceway segment(s) that must be included in the routing of the selected cable. Currently the user must use the Excludes property and select all the raceway they do not want to include in the routing of ...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Physically model Cable Tray Barriers.

Would like cable tray barriers to be modeled inside the trays so that designers and clients can see that a tray has dividers.
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

BOLT selection for multiple materials or records

OPM_CALCULATE_BOLT_LENGTH = 1 and ALLOW_BOLT_INCREMENTING = 1 OPM finds multiple records that meet Nominal Diameter, Facing and Rating. Bolt Length for multiple records less than the OPM calculated value. When all three of the above criteria is me...
2 months ago in OpenPlant Modeler 0 Future consideration