Option to Create Instrument like Create Equipment

Currently we have the feasibility to create intelligent Equipment from parametric solid independently similary we should have ability to create smart instrument from custom geometry.We cannot use Class as Custom component from Piping tab because i...
11 months ago in OpenPlant Modeler 5 Future consideration

Add Duct Bank Sheet Spacers Option

Current construction trend is to utilize duct bank sheet spacers instead of typical snap-loc spacers that are inclued in BRCM. It would be great if Bentley could add the ability to select sheets as an option. Sheet do not require any separate base...
about 2 months ago in Bentley Raceway and Cable Management 0 Future consideration

Exposing OpenPlant API via VBA/Python

Bentley shall consider exposing the OpenPlant API via Python/VBA. 1. Expose the API: Bentley needs to create bridges or wrappers that allow both Python/VBA to interact with OpenPlant API functions. 2. Integrate Schemas: Ensure that the schem...
about 2 months ago in OpenPlant Modeler 0 Future consideration

Change Spec of Custom Piping Component

When we change the spec of a Custom Piping Component, the graphics are reset to OPM default 3D Geometry
over 1 year ago in OpenPlant Modeler 2 Future consideration

Ability to Add PlantSight Only Properties in Bulk

Hi,Using OpenPlant Project Admin, we can add a PlantSight only Property but we can do this operation one. Meaning that if I need to add 30 string properties, I have to perform it 30 times. It would be great to have ability to create properties in ...
4 months ago in OpenPlant Project Administrator 0 Future consideration

Enable spec validation to update bolts and gaskets.

Spec validation tool allows mass model updates when specifications are updated. Often specs are in early design stages when modeling starts. When bolts or gaskets have updates, replacing these components as currently setup takes a significant amou...
almost 1 year ago in OpenPlant Modeler 2 Future consideration

Ability to add the File Name to Piping Components

In a File Based CAD Environment, the File Name is used to identify systems and other details about a model. Currently, users need to add this data manually to different piping and equipment components. When a file name changes, we find that design...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to Update Physical & Functional Name Property Value in Bulk

In PlantSight integrated mode, there is no mechanism to update the existing tag name in bulk. Only editing can be done for those property which are not part of name property. In practical cases, Name property requires its modification based and it...
4 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Validate from Spec using user defined properties

When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
over 1 year ago in OpenPlant Modeler 1 Future consideration

Stage -Save should Update Associated properties aswell

OPPID -OPM plantSight integration 1.P&ID are synced to PlantSight successfully first time.If everything is properly defined then all pipelines are reflected into Browse option of OPM.After linking P&ID tags into OPM Modeled pipeline/compon...