Add support custom xml schema

Users add customization to OpenPlant_3D.01.08.ecschema.xml and other Supplemental schemas. They want to have one separated schema where will be available option to create new classes and properties and not change initial schemas. This will help to...
over 3 years ago in OpenPlant Modeler 1 Future consideration

Instrument attaching to equipment

There are many instruments attaching on equipment via. nozzle and current OPM doesn't have a capability to do this. Please provide this feature.
11 months ago in OpenPlant Modeler 0 Future consideration

Ensuring Custom information header in reference does not disappear when published to Imodel

Dear Project Admin, our custom project information header disappear whenever we publish to imodel. This information can be found in the nested reference files of our main container file. When we are giving to our client the main container model, t...
4 months ago in OpenPlant Modeler 1 Future consideration

Piping AutoRouting via “AutoPath” or “Connect to.." options.

Currently we don’t have such functionality in OP compared to what we have available in AutoPLANT Modeler. In some cases, it would be very helpful and more productive to automatically finish the pipe routing with possible alternative routing option...
about 4 years ago in OpenPlant Modeler 0 Future consideration

Pipe components properties into Itemtypes using Expressions

This is a feature we currently use in Prostructures to get Steel information into Item types via expressions such as this.GetElement.Length(). We would like to be able to do this with Piping components in OPM which would make our exports consisten...
8 months ago in OpenPlant Modeler 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
8 months ago in OpenPlant Modeler 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
8 months ago in OpenPlant Modeler 0 Future consideration

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
8 months ago in OpenPlant Modeler 0 Future consideration

Import attributes from Excel

We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
about 1 year ago in OpenPlant Modeler 1 Future consideration

LUG JOINT type calculation to add in OPM

LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE. Logging on behalf of E365 user - Stantec Consulting - Australia
almost 2 years ago in OpenPlant Modeler 2 Future consideration