Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
Status Future consideration
Workspace OpenPlant Modeler
Created by Guest
Created on Jan 25, 2023

LUG JOINT type calculation to add in OPM

LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE.


Logging on behalf of E365 user - Stantec Consulting - Australia

How frequently will feature be used? A few times a week
How much time will you save? depends on user project quantum
Your Industry Other
  • Guest
    Reply
    |
    Nov 16, 2023

    We run into this issue quite often and the only workaround is to change the bolt length on the isometric sheet manually.

  • Guest
    Reply
    |
    Feb 1, 2023

    Lug Joint on valves needs complex calculations and the provided functionality is currently not working, well last time I tried testing this. From the wiki article this is what the calculation is meant to be. At the moment OPM seems to be ignoring the Bolt_Gap.

    Length = Flange_Thickness + Gasket_Thickness + (Valve_Length / 2) – Bolt_Gap

    Currently Lugged bolts are calculated randomly and lengths in our configuration is generated longer that even flanged connections.

    Please allow correct lugged component bolt length calculations.