OpenPlant Modeler

Showing 18

MixMetric should have ProStructures and BRCM

We are trying use BRCM and Prostructures module in OpenPlant Modeler. We can see that there is an option to enable the module in OpenPlant Project Administrator for Metric and Imperial projects but we do not see that in the MixMetric projects. Kin...
30 days ago in OpenPlant Modeler 0 Needs review

OpenPlant i.DGN Data in Navisworks

All our customers request data rich 3D Models and the ability to view OpenPlant EC data in Navisworks as this is the most common review tool used in the industry. Currently, Autodesk is using the Bentley SDK and is capable of viewing i.dgn data ho...
about 1 month ago in OpenPlant Modeler 0 Needs review

Ability to update properties on multiple components

CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
2 months ago in OpenPlant Modeler 0 Needs review

Calculate COG for assembly models

We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
about 2 months ago in OpenPlant Modeler 0 Needs review

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
about 1 month ago in OpenPlant Modeler 0 Needs review

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
about 2 months ago in OpenPlant Modeler 0 Needs review

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
about 2 months ago in OpenPlant Modeler 0 Needs review

Height of Stanchion for Simple Elbow Support should be from a specific point

When a Simple Elbow Support is placed, the height of the stanchion starts at a location of the support that seems to be a random location on the elbow (see STANCHION.png). The height should be from the center of the pipe end of the elbow (see STAN...
2 months ago in OpenPlant Modeler 0 Needs review

Improved Data Exchange with STP files

Our suppliers and customers utilize STP files to exchange equipment models to/from other authoring tools. However, the data structure of different elements is lost in Openplant. Further, when piping models are exported as STP files they do not con...
about 1 month ago in OpenPlant Modeler 0 Needs review

Ability to place support nodes on Valves/Custom Components

Currently, there is no way to add support nodes to Valves or Custom Compoenets.
about 1 month ago in OpenPlant Modeler 0 Needs review