Generate ISO from OPM HVAC elements.

User want to Generate ISO drawings from OPM HVAC elements. They want to create ISO drawings from rectangular, oval, round HVAC duct lines.
over 3 years ago in OpenPlant Isometrics Manager 0 Future consideration

Promote Centerlines should work for equipment

Under View Attributes - OpenPlant Modeler Settings - Promote - Centerlines only activates centerlines for piping. In orthographic drawing production, equipment also is displayed with centerlines. Centerlines should be displayed in all views of the...
almost 2 years ago in OpenPlant Modeler 2 Future consideration

Custom Components to align to pipe automatically

Please can you allow custom components to align to the pipe automatically. Placing custom components on sloped lines are very time consuming as these need to be rotated manually using 3 point rotation, which does not always work on first attempt. ...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
almost 2 years ago in OpenPlant PID 0 Future consideration

Add Thomas&Betts raceway catalogs to metric dataset

A user requested to add the Thomas&Betts catalogs available in imperial dataset to metric dataset.
almost 2 years ago in Bentley Raceway and Cable Management 0 Future consideration

Ability to access Synchro Control from PlantSight iTwin

We want to utilize Synchro Control in the later phase our PlantSight integrated OPM project. At current stage, we can't do this as it doesn't support.
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Select element in model and found it in Item browser

User want to select component in 3D model and quickly found it in Item browser tree. Andrey
over 3 years ago in OpenPlant Modeler 0 Future consideration

User interface to edit ProductCode (PCODE) in parametric Equipment

It will save a lot of time and will be easier to set the PCODE in a user interface, e.g. in Equipment Manager instead of editing the CAT_EQP_PCode_EN.xml manually. To get the required info, it will be necessary to enable macros in this file to han...
almost 2 years ago in Bentley Raceway and Cable Management 0 Future consideration

Extraction overwrites Voltage Level to generate drawing levels in different colors

i saw a request to visualize the raceway voltage level in 2D extraction in different color (drawing level).
almost 3 years ago in Bentley Raceway and Cable Management 0 Future consideration

Untagged Parametric Instrument bubble

In general User needs sometimes untagged ( components without unique identifier). Example instrument bubbles with the same behavior than the existing ones but without any sequence number. Example PLC Entry Points. See attached document.
almost 4 years ago in OpenPlant PID 1 Future consideration