Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 266

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
3 months ago in OpenPlant Modeler 0 Future consideration

Enable the Change Text Attributes

It makes it easier to change the text attributes, it's enabled in Microstation.
3 months ago in OpenPlant Modeler 0 Future consideration

Calculate COG for assembly models

We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
3 months ago in OpenPlant Modeler 0 Future consideration

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
3 months ago in OpenPlant Modeler 0 Future consideration

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
3 months ago in OpenPlant PID 0 Future consideration

Ability to update properties on multiple components

CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
3 months ago in OpenPlant Modeler 0 Future consideration

Create an Advanced Query Function that can pull Class UOM

Create an ECSQL built-in function like ‘ec_clanname() and ‘ec_classid()’. It could have this form: ec_getPropertyUnit( ecclass, ecproperty ) Its functionality is to pull the component's unit of measurement (UOM).
3 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Height of Stanchion for Simple Elbow Support should be from a specific point

When a Simple Elbow Support is placed, the height of the stanchion starts at a location of the support that seems to be a random location on the elbow (see STANCHION.png). The height should be from the center of the pipe end of the elbow (see STAN...
3 months ago in OpenPlant Modeler 0 Future consideration

Oval Instrument Parametric bubbles - Other functions

At the moment the Oval bubbles (Place Instrument Parametric) are only available as discrete instruments. Please can you extend the oval bubbles to also include the other functions like: Computer Function Distributed Digital Distributed Analog
4 months ago in OpenPlant PID 0 Future consideration

Connections between different component sizes

We use OPM_MATCH_PROPERTY_MAP_NOMINAL_DIAMETER variable in our projects for Poly to Steel pipe size mapping. This variable works only when you comment out OPM_ATTRIBUTESTOCHECK variable which is not ideal solution because it allows connection betw...
5 months ago in OpenPlant Modeler 0 Future consideration