Import attributes from Excel

We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
6 months ago in OpenPlant Modeler 0 Future consideration

Wafer Bolt - Two bolts in the spec with the same nominal diameter and BOLT_LEN but different Description, OPM picks the first spec entry.

OpenPlant Modeler’s working behavior is to pull the nearest bolt entry from spec with a lower BOLT_LEN compared to the calculated length if there’s no available bolt entry from spec with a BOLT_LEN that is either equal or greater than the calculat...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Assembly Manager in OPM

Users would be able to place multiple OPM-components in one go by creating a user defined component library, with retaining individual properties per component. Todays´ capabilities don´t hold individual properties (place custom component from cel...
over 2 years ago in OpenPlant Modeler 1 Future consideration

Supports placement on Fittings, tees, elbows etc. and supports customization as primary and secondary.

At present we cannot place U-bolts or support locators on fittings, elbow and tees as a result in Isometric we need to add these supports manually and get it counted in the BOM. We need more options to create customized supports as primary and sec...
over 2 years ago in OpenPlant Modeler 1 Planned

Ability to Delete Component along with Tag in Plantsight from OPM directly

In an instance Component was placed in OPM and was pushed to Plantsight.We were not able to checkout the component through any associated item as it was not reflected in PlantSight explorer tab.If we verify it is only into Physical Properties not ...
2 months ago in OpenPlant Modeler 1 Will not implement

Validation of Component Dimensions

OPM users need a way to check dimensions of components against the pipespecs. We have had several instances where pipespec dimensions get updated by piping engineering after OPM Users have already routed in the model. OPM users currently have no w...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Nozzle Manager - Enable property DEVICE_TYPE_CODE to define Unique NOZZLE tag along with NUMBER.

Currently a Nozzle in Nozzle Manager is defined by the NUMBER field. When using PlantSight/OPPID/OPM, the Number needs to be defined as a Number - Not N1 or M1 (Nozzle or Manhole). Tagging of a nozzle is generally defined as EQP_NO-DEVICE_TYPE_COD...
3 months ago in OpenPlant Modeler 0 Needs review

Add support custom xml schema

Users add customization to OpenPlant_3D.01.08.ecschema.xml and other Supplemental schemas. They want to have one separated schema where will be available option to create new classes and properties and not change initial schemas. This will help to...
almost 3 years ago in OpenPlant Modeler 1 Future consideration

LUG JOINT type calculation to add in OPM

LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE. Logging on behalf of E365 user - Stantec Consulting - Australia
about 1 year ago in OpenPlant Modeler 2 Future consideration

OpenPlant - External Report OPM - file name inc ref - Requested by Shell - Tim Zahn

When running a report in OpenPlant Model with a reference file attached I require to have afield in the report to show the reference file name. Simple example attached, This is a reference file with a valve and pipe, and the active file has the sa...
9 months ago in OpenPlant Modeler 1 Future consideration