Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 309 of 309

Report of Flange Face Coordinates on Piping Components

Need the ability to run a report on Nozzle and Flanges to report Coordinates, Orientation and other Properties (Connection Number, Type, Rating, Diameter)
about 1 year ago in OpenPlant Modeler 1 Future consideration

Raceway ID and Assignment Tool - "Export" and "Import" function

The Raceway ID and Assignment tool can enhanced its functionality by incorporating the "Export" and "Import" functions, allowing for the seamless assignment of new IDs to existing segments. This streamlined ID assignment process can proves highly ...
10 months ago in Bentley Raceway and Cable Management 1 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
2 months ago in OpenPlant Modeler 0 Future consideration

Need FROM/TO for PIPING_NETWORK_SYSTEM

Hi, Currently it's only possible to get FROMs/TOs for PIPING_NETWORK_SEGMENT. It's a very important part of our engineering process/workflow to have from FROMs/TOs for a whole line (PIPING_NETWORK_SYSTEM). FROM/TO for a line can one of the followi...
2 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
2 months ago in OpenPlant Modeler 0 Needs review

One button for Move Label and Modify Element

Users would save considerable amount of time if the functionality of Move Label and Modify Element is combined into one button. Currently, users have to swap between two buttons constantly to clean up labels on an isometrics. A combined button wou...
almost 2 years ago in OpenPlant Isometrics Manager 1 Planned

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
3 months ago in OpenPlant Modeler 0 Needs review

Concatenating the multiple User defined attributes to form separate Tag format

looking for Combined Properties Tags in BRCM, on basis of properties which can be having different kind of values, which can be selected from Picklist, drop down menu and different options
10 months ago in Bentley Raceway and Cable Management 0 Future consideration

Structure and Column Grid Management updates

Structure and Column Grid Management updates OpenPlant Modeler and BRCM need a consistent and easy to use Structure and Column Grid Manager that users can work with to get quick reference points while locating equipment and routing piping. Ideally...
about 1 year ago in OpenPlant Modeler 1 Future consideration

Allow offset for valve operators

We often have valves where the operators do not sit in the center of the valve body. We need the ability with in the specs to account for that offset and to be properly represented in the model. Currently only gearbox operators allow for this offs...
7 months ago in OpenPlant Modeler 0 Future consideration