AUTOPLANT SCHEMA ISSUE

SrvReqNo:[7001545099]} AUTOPLANT SCHEMA ISSUE Currently, the iTwin platform uses Microstation Bridge to view EC data generated in OPM. However, the AutoPlant schema cause several properties to be corrupted and not visible. OPM service team has ins...
over 3 years ago in OpenPlant Modeler 2 Future consideration

Routing Auto Elbows with multiple elbows in spec

We have specifications where multiple end preparations exist for elbows with the same size. Typically we have butt welded and threaded elbows for the same size pipe depending on the service. When you have 2 different types of elbows for the same s...
over 3 years ago in OpenPlant Modeler 3 Already exists

Raceway routing enhancements

Please can you enhance the race way routing to also automatically place bends, tees and reducers in much the same way as piping does. At the moment you have to route a straight section then place the bend which does not have a center insert point ...
over 3 years ago in OpenPlant Modeler 2 Already exists

Validate property on component creation

We should have capability to cancel component creation/placement if some properties are not consistent. In Plantspace we can't place component if mandatory property are not filled or some geometry values are not consistent.For example in OPM, we c...
over 3 years ago in OpenPlant Modeler 2 Future consideration

UI Larger font size

There is a lot of text in each UI view, and the font size cannot be changed.
almost 4 years ago in OpenPlant Project Administrator 0 Future consideration

Change existing bend radiuses of multiple selection

The user ask to change multiple bends to other bend radius, a selection or a raceway run from source to target.
about 4 years ago in Bentley Raceway and Cable Management 0 Future consideration

Save last settings in AutoPlace Conduit commands

I got multiple user requests to use save the settings in the AutoPlace conduit commands to be used if the commands are restarted. Perfect will be the possibility to save different settings to use in the project.
about 4 years ago in Bentley Raceway and Cable Management 1 Planned

Add Underfloor Trunking systems to raceway content

In Buildings often it is required to use underfloor trunking systems to feed e.g. user desks with computer etc. An example is system from OBO
about 4 years ago in Bentley Raceway and Cable Management 0 Future consideration

Option to update to Plantsight graphic only elements

There is the need to add/modify graphic elements that are not PID components (notes, details, etc.). There should be an option/command to update in Plantsight the graphics elements that are part of the P&ID without the need of a dummy change i...
about 4 years ago in OpenPlant PID 0 Future consideration

Include consistency checker

We should have the consistency checker from openplant modeler available in brcm in order to import equipment tags directly from PID.
over 4 years ago in Bentley Raceway and Cable Management 2 Future consideration