Ability to assign null values to Long, Int, Double type properties in OPM Schemas
Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
Piping AutoRouting via “AutoPath” or “Connect to.." options.
Currently we don’t have such functionality in OP compared to what we have available in AutoPLANT Modeler. In some cases, it would be very helpful and more productive to automatically finish the pipe routing with possible alternative routing option...
Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches
PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
Height of Stanchion for Simple Elbow Support should be from a specific point
When a Simple Elbow Support is placed, the height of the stanchion starts at a location of the support that seems to be a random location on the elbow (see STANCHION.png). The height should be from the center of the pipe end of the elbow (see STAN...
We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE. Logging on behalf of E365 user - Stantec Consulting - Australia
OpenPlant Modeler users would benefit from .PCF import when there is a need to import models from other Plant Design software. This import process could, at first, bring basic routing and piping accessories, letting users select which OpenPlant sp...
OPM_CALCULATE_BOLT_LENGTH = 1 and ALLOW_BOLT_INCREMENTING = 1 OPM finds multiple records that meet Nominal Diameter, Facing and Rating. Bolt Length for multiple records less than the OPM calculated value. When all three of the above criteria is me...
"Save-As" or "Copy/Rename" of a Model connected to PlantSight should change GUID
When using OpenPlant modeler with a project connected to PlantSight, you cannot perform a "Save as" or "Copy and rename". This is because when you do “Save As” or “Copy” on A.DGN to lets say B.DGN, the GUID of the model is not changed. Plantsight ...