Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant PID

Showing 48

Would like the ability to pass a pipe run property value to a property on a valve class

Story Narrative As a piping designer, I would like the ability to define a custom PROPERTY_X1 on Pipe Run class to pass its values to PROPERTY_X2 on Valve class component, but only as default value and only for first time. The goal is for the targ...
about 1 year ago in OpenPlant PID 0 Future consideration

Leader line for pipeline annotations

possibility to draw leader lines for pipeline annotations if there is no space on the line.
almost 4 years ago in OpenPlant PID 0 Future consideration

Create Custom Report with Component Reference to PID Drawing

Create a new custom PID Report that includes the PID drawing number where the component resides.
about 4 years ago in OpenPlant PID 3 Future consideration

Valve Reporting for Connected Different Pipelines

Hi, We have requirement of valve reporting, where valve is connected to two different pipelines. Meaning, CP1 of valve is connected to pipeline A and CP2 of valve is connected to different pipeline B. Whenever, valve report is extracted it should ...
over 1 year ago in OpenPlant PID 0 Future consideration

Option to update to Plantsight graphic only elements

There is the need to add/modify graphic elements that are not PID components (notes, details, etc.). There should be an option/command to update in Plantsight the graphics elements that are part of the P&ID without the need of a dummy change i...
over 2 years ago in OpenPlant PID 0 Future consideration

Background Automated Data Synchronization

the way synchronization works is it checks DGN vs DB and compare them.. in the process of it, the software asks the user to "Please wait...", prompts differencing dialog (which users usually ignore).. and data is not "synched" some changes by othe...
over 2 years ago in OpenPlant PID 0 Future consideration

Place assembly as a group with a report

We have the option to place an created assembly as individual components or as an complete assembly. Some customer want to create schedules/reports over placed assemblies and the referring components. Requirements Add option when inserting assembl...
over 3 years ago in OpenPlant PID 0 Future consideration

We need 3-Way components under 45 Degrees. Control valves , valves and Fittings

Placing a 3 Way Valve with third Way under 45 Degrees should be possible . Same should be possible for 3-Way Fittings ( Y-Strainer). Example see attached pictures. Needed for different customers. They as well add valves directly to the third way, ...
over 3 years ago in OpenPlant PID 2 Planned