Allow offset for valve operators

We often have valves where the operators do not sit in the center of the valve body. We need the ability with in the specs to account for that offset and to be properly represented in the model. Currently only gearbox operators allow for this offs...
about 1 year ago in OpenPlant Modeler 0 Future consideration

System Iso drawing

There is no way to create System Isometric drawing in the OpenPlant Modeler using OPIM tool. This was possible in AutoPLANT XM and V8, at least when it was using Isogen engine. And in OpenPlant V8i it was possible to do. Sometimes users need to cr...
almost 2 years ago in OpenPlant Isometrics Manager 0 Future consideration

Measurement Legend will help new user to model supports fast and avoid confusion.

Currently, it can be seen, the image of support while placing in OPSE upon hovering on it. Requirement here is to get the option in placement dialogue of supports in OPSE in which one can see the image of support to place with the legend of dimens...
8 months ago in OpenPlant Support Engineering 0 Future consideration

Ability to auto perform connectivity check

If Openplant can detect and connectivity error and display it as an error to the user, it should be able to automatically run connectivity check. At the very least, "Run Connectivity Check" should be added as a button to the disconnect error dialo...
3 months ago in OpenPlant Modeler 0 Future consideration

Ability to view models from more than 1 folder location in collaboration Manager

When using projectwise and managed workspace we have models in 2 folder locations. Currently BRCM one can only see models from the location you opened the model. We need to be able to see multple folder locations as we do a lot of worksharing.
over 1 year ago in Bentley Raceway and Cable Management 1 Future consideration

Assign location info from Architecture Room Space to BRCM equipment UDA.

It will be useful to get the location info (room/area name) from OBD-Architecture room spaces into BRCM equipment UDA via file reference with a command for a selection of equipment.
3 months ago in Bentley Raceway and Cable Management 0 Future consideration

希望opim中的bom表支持按中文习惯控制首尾字符

如附件图示,出现这类问题的情况很多。不止’,’一个标点,希望处理。
5 months ago in OpenPlant Isometrics Manager 0 Needs review

BRCM for data transfer from properties fields to the data base

We need help in order to sync the BRCM properties filed to BRCM Data Base which currently not possible. Taking example of ID here If we manually edit the ID filed within properties window of raceway it allows us to edit it however the changes made...
over 1 year ago in Bentley Raceway and Cable Management 1 Already exists

Assembly Manager in OPM

Users would be able to place multiple OPM-components in one go by creating a user defined component library, with retaining individual properties per component. Todays´ capabilities don´t hold individual properties (place custom component from cel...
almost 3 years ago in OpenPlant Modeler 1 Future consideration

Supports placement on Fittings, tees, elbows etc. and supports customization as primary and secondary.

At present we cannot place U-bolts or support locators on fittings, elbow and tees as a result in Isometric we need to add these supports manually and get it counted in the BOM. We need more options to create customized supports as primary and sec...
about 3 years ago in OpenPlant Modeler 1 Planned