Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 80

Fix and Enhance the Details(Items) Dialog so it's usable.

Currently the Details (Items) dialog will show a list of what ever has been selected. Option to sort dialog, defaults back 'Item' when working on data past the first page of data, (scroll down past the first 20 lines say) When a number of items ar...
8 days ago in OpenPlant Modeler 0 Future consideration

Pipes and Breaks VBA

We have found a VBA that add the finish illustration of piping, the VBA also has option for cutting the pipe. YouTube: https://www.youtube.com/shorts/U7oqHvl1eMY Communities: https://communities.bentley.com/products/programming/microstation_progra...
14 days ago in OpenPlant Modeler 1 Future consideration

MixMetric should have ProStructures and BRCM

We are trying use BRCM and Prostructures module in OpenPlant Modeler. We can see that there is an option to enable the module in OpenPlant Project Administrator for Metric and Imperial projects but we do not see that in the MixMetric projects. Kin...
about 2 months ago in OpenPlant Modeler 0 Future consideration

Improved Data Exchange with STP files

Our suppliers and customers utilize STP files to exchange equipment models to/from other authoring tools. However, the data structure of different elements is lost in Openplant. Further, when piping models are exported as STP files they do not con...
2 months ago in OpenPlant Modeler 0 Future consideration

Pipe components properties into Itemtypes using Expressions

This is a feature we currently use in Prostructures to get Steel information into Item types via expressions such as this.GetElement.Length(). We would like to be able to do this with Piping components in OPM which would make our exports consisten...
2 months ago in OpenPlant Modeler 0 Future consideration

Spec Grid Record for Operators Upon Valve Placement in OpenPlant Modeler

In OpenPlant Modeler, we have only one option to place valve, meaning we dont have valve with Open and Closed type for its placement. As per standard, for open and closed type of valve we have different operator length. At present in OpenPlant Mod...
2 months ago in OpenPlant Modeler 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
2 months ago in OpenPlant Modeler 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
3 months ago in OpenPlant Modeler 0 Future consideration

Enable the Change Text Attributes

It makes it easier to change the text attributes, it's enabled in Microstation.
3 months ago in OpenPlant Modeler 0 Future consideration

Calculate COG for assembly models

We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
3 months ago in OpenPlant Modeler 0 Future consideration