All ideas

Showing 277

MixMetric should have ProStructures and BRCM

We are trying use BRCM and Prostructures module in OpenPlant Modeler. We can see that there is an option to enable the module in OpenPlant Project Administrator for Metric and Imperial projects but we do not see that in the MixMetric projects. Kin...
4 months ago in OpenPlant Modeler 0 Future consideration

Validate from Spec using user defined properties

When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
about 1 year ago in OpenPlant Modeler 1 Future consideration

Raceway covers

Currently in BRCM are two settings related to covers. One is located in properties of the raceway, in UDAs as "Cover Type". It's needed to use it to include covers in BOQ. Second setting is hidden in the fitting catalogue definition per raceway ty...
4 months ago in Bentley Raceway and Cable Management 0 Future consideration

BOLT LENGTH FROM SPEC + WAFER JOINTS

OPM has a config variable OPM_CALCULATE_BOLT_LENGTH which controls if the tool automatically calculates the required bolt length or uses the value from the Spec. We would like to use the values defined in our spec in all cases, except for Wafer ty...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Stretch/Move multiple lines at the same time

Please consider allowing the user to stretch/move multiple lines including all components and equipment while maintaining connectivity. Typical examples are in pipe racks where you wish to move multiple pipes together in the same spacing, or movin...
about 2 months ago in OpenPlant Modeler 0 Future consideration

Set a custom ACS in OPM and have it recognized by OPIM

Currently, OPIM does not recognize the custom ACS and only displays coordinates according to the default origin. However, it would be beneficial if we could set a custom ACS in OPM and have it recognized by OPIM. Related SR ticket: 7001541451
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Consolidate Bentley Class Editior Workflows in OPPA

There are several functions such as schema modification and custom attribute addition/removal/modification that is not possible via OPPA. Users have to switch between multiple tools to complete tasks. It would be beneficial to consolidate all thes...
over 1 year ago in OpenPlant Project Administrator 0 Future consideration

Merge into Master should be supported in OpenPlant Modeler

In MicroStation, and other design tools like OpenBuildings Designer, the reference tool -Merge Into Master is supported. In OpenPlant Modeler, this is not supported and removes the EC Data associated to the components.
over 1 year ago in OpenPlant Modeler 4 Future consideration

To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
over 1 year ago in OpenPlant PID 0 Future consideration

Raceway ID and Assignment Tool - "Export" and "Import" function

The Raceway ID and Assignment tool can enhanced its functionality by incorporating the "Export" and "Import" functions, allowing for the seamless assignment of new IDs to existing segments. This streamlined ID assignment process can proves highly ...
about 1 year ago in Bentley Raceway and Cable Management 1 Future consideration