Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 347

Additional cable laying method related to cable size

A user like to use an additional cable laying method related to the cable size. That mean cable with a specified diameter shall be routed single layer and all cable smaller shall be routed multi layer, also the two laying methods shall be separate...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Construction attribute in Element Templates

You can assign the Construction attribute in Element Templates but when the OPM objects are drawn, the Construction assignment isn't honored. You can manually select the Template in the object's properties, but it would be good if the Construction...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Support for variable IE_PLANTNORTH

E365 User (Tetratech) looking forward to utilize both option coordinates and rotation using variable IE_PLANTNORTH present in style.cfg file. in case there is no option to support here - then we can introduce new variable to allow user to rotate i...
about 3 years ago in OpenPlant Isometrics Manager 0 Planned

Update UI for Change Spec Tool

The current Change Spec tool UI doesn't allow users to easily compare the old components with the new components. Why doesn't the UI show both the old data on the left, and the new data on the right in a comparable table. See attached screenshot. ...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
about 1 year ago in OpenPlant PID 0 Future consideration

Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
about 1 year ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
about 1 year ago in OpenPlant PID 0 Future consideration

Would like a Progress Message displayed during PlantSight synchronization

Whenever you push drawing records to PlantSight, it will prompt you with the Difference Dialog. Once we click on Sync it took time to reflect the dialog for "Please enter comments" but during that phase (difference dialog to comment dialog) there ...
about 1 year ago in OpenPlant PID 0 Future consideration

UI to set raceway PCODE

It will be good to have an UI to set PCODE settings and possible Accessories. If possible a copy paste will be useful to copy e.g. Accessories (or other entries) from one raceway fitting to others also to other catalogs.
over 3 years ago in Bentley Raceway and Cable Management 0 Future consideration

Refresh 3D cable

In case a 3D cable is visualized and the user need to e.g. move connected equipment but the same routing, in the moment it need to search and delete the related 3D cable, restart Cable Manager, Update length and visualize the 3D cable again. I gue...
over 3 years ago in Bentley Raceway and Cable Management 0 Planned