Better Debugging Abilities

If we're going to have applications like this use cfg variables, the better debugging abilities are required for those of use with customised builds.
almost 3 years ago in OpenPlant Project Administrator 0 Future consideration

Query Component function

It is useful to search and select a piece of the line. I use it to see if I have any double pieces.
12 months ago in OpenPlant Modeler 2 Needs review

Activate/Deactivate feature for reference files

OBD has Activate/Deactivate feature for reference files. This allows users to edit the reference files in the same session without switching to the reference model. Our mechanical team is currently using OBD for equipment modeling and they use thi...
12 months ago in OpenPlant Modeler 2 Future consideration

Integrate OpenPlant Data Manager with teams

Integrate OpenPlant Data Manager with teams similar to iTwin integration
about 4 years ago in OpenPlant Engineering Data Manager 0 Future consideration

Possibility to change flow arrow note dimensions

When we are placing flow arrow note in our models, if the piece of pipe is too small, the placement of the note is note working well. Most of the time we have to stretch the pipe to a bigger dimensions, place the arrow and the stretch back the pip...
about 1 year ago in OpenPlant Modeler 0 Future consideration

OpenPlant has no Mechanical Joint Valves

OpenPlant has no Mechanical Joint Valves. Some companies commonly used are AWWA and Mueller.
about 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to have Driver as a parametric cell upon Placement

We can place driver on an Equipment as shown in attached image, but the only possible stretch is vertically or horizontally and you cannot add vertices to the line coming off the driver to adjust that length.
about 1 year ago in OpenPlant PID 0 Future consideration

Support for variable IE_PLANTNORTH

E365 User (Tetratech) looking forward to utilize both option coordinates and rotation using variable IE_PLANTNORTH present in style.cfg file. in case there is no option to support here - then we can introduce new variable to allow user to rotate i...
over 3 years ago in OpenPlant Isometrics Manager 0 Planned

Update Reports to include Component Reference to PID Drawing

We would like to have the PID Drawing Number of where components are located in the following standard reports (like we already do with the process line list) so that it's easy to locate which drawings they are found in: Equipment Report Instrumen...
about 1 year ago in OpenPlant PID 0 Future consideration

Additional cable laying method related to cable size

A user like to use an additional cable laying method related to the cable size. That mean cable with a specified diameter shall be routed single layer and all cable smaller shall be routed multi layer, also the two laying methods shall be separate...
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration