Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant PID

Showing 48 of 309

Update Reports to include Component Reference to PID Drawing

We would like to have the PID Drawing Number of where components are located in the following standard reports (like we already do with the process line list) so that it's easy to locate which drawings they are found in: Equipment Report Instrumen...
7 months ago in OpenPlant PID 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 3 years ago in OpenPlant PID 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
over 1 year ago in OpenPlant PID 0 Future consideration

Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
8 months ago in OpenPlant PID 0 Future consideration

Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
8 months ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
8 months ago in OpenPlant PID 0 Future consideration

Would like a Progress Message displayed during PlantSight synchronization

Whenever you push drawing records to PlantSight, it will prompt you with the Difference Dialog. Once we click on Sync it took time to reflect the dialog for "Please enter comments" but during that phase (difference dialog to comment dialog) there ...
8 months ago in OpenPlant PID 0 Future consideration

Allow Multiple selection for changing pipeline type

Currently the pipeline type can be changed for only one pipeline at a time because it does not allow multiple selection. It would be nice if we had the ability to change the pipeline type for multiple pipelines in one go.
8 months ago in OpenPlant PID 0 Future consideration

Merge Pipe Runs tool should merge non colinear segments

Currently in OPPID the Merge Pipe Runs tool only merges colinear segments. See attached video of how you need to workaround the limitation. It would be helpful if the Merge Pipe Runs tool could merge non-colinear segments as well. By enhancing thi...
8 months ago in OpenPlant PID 0 Future consideration

Add a key-in to remove an Associated Item value (SYSTEM)

In some situations, I may wish to remove an associated item property (i.e. SYSTEM) from existing components and documents. For example, I may want to reuse existing documents for a new project that has a different tagging convention and doesn't ne...
8 months ago in OpenPlant PID 0 Future consideration