Property Category to be Defined on the Property

Currently, when adding a property or editing an existing property, the category in which the property is to reside, is defined in a separate Custom Attribute. If a user manually adds this custom attribute, it is possible to type in an incorrect na...
over 1 year ago in OpenPlant PID 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
almost 3 years ago in OpenPlant PID 0 Future consideration

Untagged Parametric Instrument bubble

In general User needs sometimes untagged ( components without unique identifier). Example instrument bubbles with the same behavior than the existing ones but without any sequence number. Example PLC Entry Points. See attached document.
almost 5 years ago in OpenPlant PID 1 Future consideration

Ability to have Driver as a parametric cell upon Placement

We can place driver on an Equipment as shown in attached image, but the only possible stretch is vertically or horizontally and you cannot add vertices to the line coming off the driver to adjust that length.
about 2 years ago in OpenPlant PID 0 Future consideration

Would like ability to rename the category labels in the Standard Preferences dialog

It would be helpful if we had the ability to rename the category labels in the Standard Preferences dialog as highlighted in the attached screen capture.
about 2 years ago in OpenPlant PID 0 Future consideration

Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
about 2 years ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
about 2 years ago in OpenPlant PID 0 Future consideration

Allow Multiple selection for changing pipeline type

Currently the pipeline type can be changed for only one pipeline at a time because it does not allow multiple selection. It would be nice if we had the ability to change the pipeline type for multiple pipelines in one go.
over 2 years ago in OpenPlant PID 0 Future consideration

Merge Pipe Runs tool should merge non colinear segments

Currently in OPPID the Merge Pipe Runs tool only merges colinear segments. See attached video of how you need to workaround the limitation. It would be helpful if the Merge Pipe Runs tool could merge non-colinear segments as well. By enhancing thi...
over 2 years ago in OpenPlant PID 0 Future consideration

Automatically reposition flow arrows to avoid overlapping inline components

In situations where the flow arrow overlaps a component on the pipeline it would be nice if the software would automatically reposition the flow arrow to avoid the overlap if possible. If there is insufficient space to display the flow arrow it wo...
over 2 years ago in OpenPlant PID 0 Future consideration