Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 309 of 309

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc.

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc. Similar to end condition mappings End Condition Extend Type for valves.
2 months ago in OpenPlant PID 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
2 months ago in OpenPlant Modeler 0 Needs review

Enable the Change Text Attributes

It makes it easier to change the text attributes, it's enabled in Microstation.
2 months ago in OpenPlant Modeler 0 Future consideration

Calculate COG for assembly models

We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
2 months ago in OpenPlant Modeler 0 Needs review

Ability to add/ edit conduit matrix after duct bank has been modelled.

Currently adding the conduit to an existing duct bank or already modelled duct bank is not possible. In projects it is very frequent to change the duct bank matrix which after modelling the duct bank. If after modelling new conduit is required to ...
2 months ago in Bentley Raceway and Cable Management 1 Planned

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
2 months ago in OpenPlant Modeler 0 Needs review

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
2 months ago in OpenPlant PID 0 Future consideration

Ability to update properties on multiple components

CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
3 months ago in OpenPlant Modeler 0 Future consideration

Create an Advanced Query Function that can pull Class UOM

Create an ECSQL built-in function like ‘ec_clanname() and ‘ec_classid()’. It could have this form: ec_getPropertyUnit( ecclass, ecproperty ) Its functionality is to pull the component's unit of measurement (UOM).
3 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Ability to Delete Component along with Tag in Plantsight from OPM directly

In an instance Component was placed in OPM and was pushed to Plantsight.We were not able to checkout the component through any associated item as it was not reflected in PlantSight explorer tab.If we verify it is only into Physical Properties not ...
3 months ago in OpenPlant Modeler 1 Will not implement