Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 100 of 309

AutoGenerate Spool IDs to skip Existing component state

Skipping components set to Existing, For Demolition or Vendor component states would be very useful because these components often don't form part of the fabrication. This needs to be an option, toggle, because sometimes when you are modelling the...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Generated "ISOSHEETS" in piping files be carried over to next file

When we create "ISOSHEETS" for pipelines in a design file and then try to copy all contents of this file into another file / new file (i.e reference in the file > select all content > Copy > Paste into new file > Detach the reference),...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Jacket Line Routing & Jacketed iso drawing

Currently, we are not able to route jacket pipe on the primary process pipe, and that's why iso drawings also do not get generated with jacketed line. Due to the feature is not available in Bentley, all these works like jacket MTC, and Iso drawing...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Custom Components to align to pipe automatically

Please can you allow custom components to align to the pipe automatically. Placing custom components on sloped lines are very time consuming as these need to be rotated manually using 3 point rotation, which does not always work on first attempt. ...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Select element in model and found it in Item browser

User want to select component in 3D model and quickly found it in Item browser tree. Andrey
about 3 years ago in OpenPlant Modeler 0 Future consideration

Ability to export IFC

OpenPlant users would benefic from better IFC integration if OPM could export, at least, basic geometries to IFC. As the IFC file format has limitations to store plant design objects, OPM objects not mapped in IFC could be translated to basic enti...
over 3 years ago in OpenPlant Modeler 3 Already exists

Allow component properties to be loaded from external files

In many cases, project designers and engineers start their 3D models without providing engineering data to modeled components. When the 3D arrangement is approved and designers/engineers need to provide detailed data, they need to modify each comp...
over 3 years ago in OpenPlant Modeler 4 Already exists

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
about 2 months ago in OpenPlant Modeler 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
2 months ago in OpenPlant Modeler 0 Needs review

Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
2 months ago in OpenPlant Modeler 0 Needs review