Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 88

The ability to report on surface area of objects for insulation reporting

We would like to be able to report on the objects surface area for insulation estimation. OPM does not have a Surface area property but a plain Microstation property exists called surface area under the cells section of the properties. Since OPM p...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Connections between ISOSHEET using PlantSight with file based

A “typical” Plantsight workflow would be that each designer is checking in all their piping and equipment each day. When it would come time to create the system iso’s, they would check out all the lines/equipment with nozzles that are part of that...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Control Over Flow Arrow Size

We need to be able to control the scale of the flow arrow so it can be placed on small section of pipe. ATM is places it out in space if the section is too small.
over 2 years ago in OpenPlant Modeler 0 Future consideration

Briefcase BIM file should only download Process physical and functional

Currently when using PlantSight, all connection files are downloaded to the BIM file to create it. This causes the BIM file to become very large and can take hours to open Openplant modeler depending on the size of the project. The request would b...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Connections between ISOSHEET using PlantSight with file based

A “typical” Plantsight workflow would be that each designer is checking in all their piping and equipment each day. When it would come time to create the system iso’s, they would check out all the lines/equipment with nozzles that are part of that...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Make Workspace and Workset Optional Like MicroStation

Not everyone wants to be forced to use the Workspace and Workset configuration. We had MicroStation change so this could be turned off for custom configurations and need to have the same for applications like OpenPlant.
almost 3 years ago in OpenPlant Modeler 2 Future consideration

Icons for different type of Instruments

While selecting an instrument from the generic option in the piping galleries we get all the instruments listed and then we need to select the required one to place in the model, instead if we have icon for the instruments for example Level switch...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to import Data Structure from STEP Files

Most of our interface partners deliver models in STEP Format. It would be beneficial to import some form of the data structure or tags from STEP Format.
over 1 year ago in OpenPlant Modeler 1 Future consideration

Specification Filter per discipline

Currently we have possibility to filter specification list from pipeline property like Service, Unit ... but this should work for all discipline HVAC, Support, Cable.As the spec folder is common for all discipline if we have dedicated spec for Hva...
over 1 year ago in OpenPlant Modeler 0 Future consideration

AUTOPLANT SCHEMA ISSUE

SrvReqNo:[7001545099]} AUTOPLANT SCHEMA ISSUE Currently, the iTwin platform uses Microstation Bridge to view EC data generated in OPM. However, the AutoPlant schema cause several properties to be corrupted and not visible. OPM service team has ins...
over 1 year ago in OpenPlant Modeler 2 Future consideration