Control Over Flow Arrow Size

We need to be able to control the scale of the flow arrow so it can be placed on small section of pipe. ATM is places it out in space if the section is too small.
about 3 years ago in OpenPlant Modeler 0 Future consideration

Reprojection of OpenPlant Models to Align to GCS

Other Bentley design tools (OBD) permit the modeling of content at the X=0, Y=0, and orientation in the X axis. When the GCS system is added to the file, and aligned to the modeled content, and the model is published to PlantSight, the components ...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Ability to import Data Structure from STEP Files

Most of our interface partners deliver models in STEP Format. It would be beneficial to import some form of the data structure or tags from STEP Format.
about 2 years ago in OpenPlant Modeler 1 Future consideration

Weight conversion from imperial units to metric units for pipe spools

Story Narrative- A specification is created in imperial units, and when one wants to use it in metric workset the numeric value of the weights is not being converted for the pipe spools. However, the numeric value of the weights is being converted...
about 2 years ago in OpenPlant Modeler 1 Future consideration

Ability to access Synchro Control from PlantSight iTwin

We want to utilize Synchro Control in the later phase our PlantSight integrated OPM project. At current stage, we can't do this as it doesn't support.
over 2 years ago in OpenPlant Modeler 0 Future consideration

Improved Data Exchange with STP files

Our suppliers and customers utilize STP files to exchange equipment models to/from other authoring tools. However, the data structure of different elements is lost in Openplant. Further, when piping models are exported as STP files they do not con...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to Delete Component along with Tag in Plantsight from OPM directly

In an instance Component was placed in OPM and was pushed to Plantsight.We were not able to checkout the component through any associated item as it was not reflected in PlantSight explorer tab.If we verify it is only into Physical Properties not ...
about 1 year ago in OpenPlant Modeler 1 Will not implement

Query Component function

It is useful to search and select a piece of the line. I use it to see if I have any double pieces.
over 1 year ago in OpenPlant Modeler 2 Needs review

Activate/Deactivate feature for reference files

OBD has Activate/Deactivate feature for reference files. This allows users to edit the reference files in the same session without switching to the reference model. Our mechanical team is currently using OBD for equipment modeling and they use thi...
over 1 year ago in OpenPlant Modeler 2 Future consideration

Possibility to change flow arrow note dimensions

When we are placing flow arrow note in our models, if the piece of pipe is too small, the placement of the note is note working well. Most of the time we have to stretch the pipe to a bigger dimensions, place the arrow and the stretch back the pip...
over 1 year ago in OpenPlant Modeler 0 Future consideration