Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches
PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
Height of Stanchion for Simple Elbow Support should be from a specific point
When a Simple Elbow Support is placed, the height of the stanchion starts at a location of the support that seems to be a random location on the elbow (see STANCHION.png). The height should be from the center of the pipe end of the elbow (see STAN...
Would like ability to rename the category labels in the Standard Preferences dialog
It would be helpful if we had the ability to rename the category labels in the Standard Preferences dialog as highlighted in the attached screen capture.
7 months ago
in OpenPlant PID
0
Future consideration
We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
It would be nice if crossing a pipeline over itself would create a jumper.
I would like the software to show a jumper when I cross a pipeline over the top of itself like it does when you have two different pipelines so that it's clear that there is not an actual joint of the pipes at that point. See attached image.
8 months ago
in OpenPlant PID
0
Future consideration
When a long description is needed to annotate a component such as a valve I have to manually input a '\n' to force some of the text to a second line. It would be nice if there was a way to specify a boundary or character length after which the sof...
9 months ago
in OpenPlant PID
0
Future consideration
Add support to connect duct bank to manholes in a referenced DGN file
Currently, BRCM does not support duct bank connections to manholes that are referenced in from another Underground file. It's very common to have multiple underground files in a project, and manholes need to support connections to these duct banks...
Please can the display rules work on higher parent classes like PIPING_NETWORK_SYSTEM (Pipeline) and PIPE_COMPONENT or ISO_SHEET. The idea is to write a rule to highlight all components in a pipeline where a specific criteria is met.
Would like the option of having the software check raceway fills when manually routing cables through raceway systems in the Cable Manager and alert the user if the fill will be exceeded.