When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
Ability to update properties on multiple components
CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
OPM has a config variable OPM_CALCULATE_BOLT_LENGTH which controls if the tool automatically calculates the required bolt length or uses the value from the Spec. We would like to use the values defined in our spec in all cases, except for Wafer ty...
We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
Merge into Master should be supported in OpenPlant Modeler
In MicroStation, and other design tools like OpenBuildings Designer, the reference tool -Merge Into Master is supported. In OpenPlant Modeler, this is not supported and removes the EC Data associated to the components.
We would like to have a tool which converts the symbols of bolts to real graphics as an option. Either a switching option to select symbol or real graphics while placing bolts or a macro that will convert all the bolt symbols to real graphics fetc...
Ability to assign null values to Long, Int, Double type properties in OPM Schemas
Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
Report of Flange Face Coordinates on Piping Components
Need the ability to run a report on Nozzle and Flanges to report Coordinates, Orientation and other Properties (Connection Number, Type, Rating, Diameter)
CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches
PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...