OpenPlant Isometrics Manager

Showing 37 of 361

Create Muti-Iso sheet without breaking pipe

In the scenario where you have a Header pipe with many branches from the header pipe, the isometric becomes cluttered and unclear. In order to place an isometric break point, you need to physically break the pipe. This creates confusion for a fabr...
about 2 years ago in OpenPlant Isometrics Manager 0 Future consideration

Publish PDF to PW365 Share and create a link to the isometric drawing in 3D model

We created powershell script for YII 2020, that will post PDF files to share for markup workflows with issue resolution. We also captured the links and used IMDM to put links to markup on each isosheet. It would be nice, if this was done automatic...
over 4 years ago in OpenPlant Isometrics Manager 0 Future consideration

Query data from iTwin and include in isometric drawing

We can use DB_QUERY to populate titleblock information from line lists that are stored in Excel or relational database. It would be nice to be able to use iTwin as a source and query these properties directly from iTwin with ECSQL as we are moving...
about 3 years ago in OpenPlant Isometrics Manager 1 Future consideration

Repeating angle symbol on the same angle one pipe unintentionally

I am logging this Idea on behalf of User. Below are the details. SR-7001518531Case Number-CS0071599Account-Mitsubishi Heavy Industries Contact-Miwako Hayasaki (miwako.hayasaki.mw@mhi.com ) User has also logged a BUG regarding this issue. Below are...
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Bentley IMS Authentication

Users are required to enter hostname:datasource for Bentley IMS login to work. Specifically, if the Datasource Name and Display Name are not the same. This is not an issue for all other Bentley products, but OPIM requires users to manually add the...
almost 2 years ago in OpenPlant Isometrics Manager 0 Future consideration

Be able to create EHT (Electrical Heat Trace) Isometrics from OpenPlant

The drafters would make a copy of piping isometric line work, scale them to fit the EHT isometric title block, and then manually add the EHT layout/Power connection/RTD location. The EHT isometric may span across multiple piping isometrics and lin...
almost 2 years ago in OpenPlant Isometrics Manager 3 Future consideration

Number " 1 " and Letter " I " come through identical in Isometric - Confusing

Number " 1 " and Letter " I " come through identical in Isometric. Which could be misleading and confusing by those who read the Isometrics.
over 2 years ago in OpenPlant Isometrics Manager 3 Already exists