Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

OpenPlant Modeler

Showing 103

Supports placement on Fittings, tees, elbows etc. and supports customization as primary and secondary.

At present we cannot place U-bolts or support locators on fittings, elbow and tees as a result in Isometric we need to add these supports manually and get it counted in the BOM. We need more options to create customized supports as primary and sec...
over 2 years ago in OpenPlant Modeler 1 Planned

Improved Data Exchange with STP files

Our suppliers and customers utilize STP files to exchange equipment models to/from other authoring tools. However, the data structure of different elements is lost in Openplant. Further, when piping models are exported as STP files they do not con...
2 months ago in OpenPlant Modeler 0 Future consideration

Wafer Bolt - Two bolts in the spec with the same nominal diameter and BOLT_LEN but different Description, OPM picks the first spec entry.

OpenPlant Modeler’s working behavior is to pull the nearest bolt entry from spec with a lower BOLT_LEN compared to the calculated length if there’s no available bolt entry from spec with a BOLT_LEN that is either equal or greater than the calculat...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to place support nodes on Valves/Custom Components

Currently, there is no way to add support nodes to Valves or Custom Compoenets.
2 months ago in OpenPlant Modeler 1 Planned

Pipe components properties into Itemtypes using Expressions

This is a feature we currently use in Prostructures to get Steel information into Item types via expressions such as this.GetElement.Length(). We would like to be able to do this with Piping components in OPM which would make our exports consisten...
3 months ago in OpenPlant Modeler 0 Future consideration

Spec Grid Record for Operators Upon Valve Placement in OpenPlant Modeler

In OpenPlant Modeler, we have only one option to place valve, meaning we dont have valve with Open and Closed type for its placement. As per standard, for open and closed type of valve we have different operator length. At present in OpenPlant Mod...
3 months ago in OpenPlant Modeler 0 Future consideration

Validation of Component Dimensions

OPM users need a way to check dimensions of components against the pipespecs. We have had several instances where pipespec dimensions get updated by piping engineering after OPM Users have already routed in the model. OPM users currently have no w...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Enable the Change Text Attributes

It makes it easier to change the text attributes, it's enabled in Microstation.
3 months ago in OpenPlant Modeler 0 Future consideration

Add support custom xml schema

Users add customization to OpenPlant_3D.01.08.ecschema.xml and other Supplemental schemas. They want to have one separated schema where will be available option to create new classes and properties and not change initial schemas. This will help to...
about 3 years ago in OpenPlant Modeler 1 Future consideration

Ability to Delete Component along with Tag in Plantsight from OPM directly

In an instance Component was placed in OPM and was pushed to Plantsight.We were not able to checkout the component through any associated item as it was not reflected in PlantSight explorer tab.If we verify it is only into Physical Properties not ...
3 months ago in OpenPlant Modeler 1 Will not implement