Would like ability to rotate elongated Instrument Bubbles in the vertical direction to save design space

As a piping designer, I use elongated shaped instrument bubbles and sometimes need to rotate them in the vertical direction to save drafting space and fit them in between pipelines. It would be nice to have a way of changing this to the vertical d...
over 1 year ago in OpenPlant PID 0 Future consideration

Unit Classification property in the OPPID KKS workset should support a pick list selection.

It would be nice if the Unit Classification property in the OPPID KKS workset had a database selection dialog when placing an Equipment, so that a user doesn't need to manually enter value. While placing such equipment in OPM, the Unit Classificat...
over 1 year ago in OpenPlant PID 0 Future consideration

NUMBER property should support user defined number of digits

This is a request to have the NUMBER property on components in all Open Plant products (Modeler, PID, Isometrics and Support Engineering), to have a user defined required number of digits. Requirements The following criteria are required: A user a...
over 1 year ago in OpenPlant PID 0 Future consideration

Would like the ability to pass a pipe run property value to a property on a valve class

Story Narrative As a piping designer, I would like the ability to define a custom PROPERTY_X1 on Pipe Run class to pass its values to PROPERTY_X2 on Valve class component, but only as default value and only for first time. The goal is for the targ...
over 1 year ago in OpenPlant PID 0 Future consideration

Untagged Parametric Instrument bubble

In general User needs sometimes untagged ( components without unique identifier). Example instrument bubbles with the same behavior than the existing ones but without any sequence number. Example PLC Entry Points. See attached document.
about 4 years ago in OpenPlant PID 1 Future consideration

Enforceable, Spec drive for P&ID

Add the ability to enfor spec drive in P&ID, or at minmum the ability to live warn a user that they are placing items that are not found in the active spec, or are not from the same spec as the line the component is being placed on.
about 1 year ago in OpenPlant PID 0 Future consideration

Valve Reporting for Connected Different Pipelines

Hi, We have requirement of valve reporting, where valve is connected to two different pipelines. Meaning, CP1 of valve is connected to pipeline A and CP2 of valve is connected to different pipeline B. Whenever, valve report is extracted it should ...
about 2 years ago in OpenPlant PID 0 Future consideration

Leader line for pipeline annotations

possibility to draw leader lines for pipeline annotations if there is no space on the line.
about 4 years ago in OpenPlant PID 0 Future consideration

Create Custom Report with Component Reference to PID Drawing

Create a new custom PID Report that includes the PID drawing number where the component resides.
over 4 years ago in OpenPlant PID 3 Future consideration

Update Reports to include Component Reference to PID Drawing

We would like to have the PID Drawing Number of where components are located in the following standard reports (like we already do with the process line list) so that it's easy to locate which drawings they are found in: Equipment Report Instrumen...