Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
over 1 year ago in OpenPlant PID 0 Future consideration

Would like a Progress Message displayed during PlantSight synchronization

Whenever you push drawing records to PlantSight, it will prompt you with the Difference Dialog. Once we click on Sync it took time to reflect the dialog for "Please enter comments" but during that phase (difference dialog to comment dialog) there ...
over 1 year ago in OpenPlant PID 0 Future consideration

Add a key-in to remove an Associated Item value (SYSTEM)

In some situations, I may wish to remove an associated item property (i.e. SYSTEM) from existing components and documents. For example, I may want to reuse existing documents for a new project that has a different tagging convention and doesn't ne...
over 1 year ago in OpenPlant PID 0 Future consideration

Place Existing Signal Page Connector include column for connected instrument line type

Place Existing Signal Page Connector should include a column for connected instrument line type. If there were multiple Signal Page Connectors available, it is currently impossible to distinguish between pneumatic, capillary, electrical, etc. Sinc...
over 1 year ago in OpenPlant PID 0 Future consideration

PID Property must reflect the change when the value is updated in the external datasource.

Would like to fetch a property from an external database and assign it to a specific component in OpenPlant PID using an external DB Query. If we update the property in the database it should reflect in the OPPID drawing as well.
over 1 year ago in OpenPlant PID 0 Future consideration

Would like to control the order that pipeline sizes are listed in the pick list

Currently OpenPlant PID automatically sorts pipeline sizes in ascending order, but it would be nice if it could take the order defined in the Class Editor when selecting the size.
over 1 year ago in OpenPlant PID 0 Future consideration

We need 3-Way components under 45 Degrees. Control valves , valves and Fittings

Placing a 3 Way Valve with third Way under 45 Degrees should be possible . Same should be possible for 3-Way Fittings ( Y-Strainer). Example see attached pictures. Needed for different customers. They as well add valves directly to the third way, ...
about 4 years ago in OpenPlant PID 2 Planned

Option to update to Plantsight graphic only elements

There is the need to add/modify graphic elements that are not PID components (notes, details, etc.). There should be an option/command to update in Plantsight the graphics elements that are part of the P&ID without the need of a dummy change i...
almost 3 years ago in OpenPlant PID 0 Future consideration

Background Automated Data Synchronization

the way synchronization works is it checks DGN vs DB and compare them.. in the process of it, the software asks the user to "Please wait...", prompts differencing dialog (which users usually ignore).. and data is not "synched" some changes by othe...
almost 3 years ago in OpenPlant PID 0 Future consideration

Place assembly as a group with a report

We have the option to place an created assembly as individual components or as an complete assembly. Some customer want to create schedules/reports over placed assemblies and the referring components. Requirements Add option when inserting assembl...
about 4 years ago in OpenPlant PID 0 Future consideration