OpenPlant Modeler

Showing 145 of 393

Consider renaming Openplant Move Button

It is bad practice to have two commands with the same name. Especially, while trying to train new users. Why is there an OpenPlant Move and a Microstation Move, but both buttons are labelled Move?
about 1 year ago in OpenPlant Modeler 0 Future consideration

AutoGenerate Spool IDs to skip Existing component state

Skipping components set to Existing, For Demolition or Vendor component states would be very useful because these components often don't form part of the fabrication. This needs to be an option, toggle, because sometimes when you are modelling the...
almost 3 years ago in OpenPlant Modeler 0 Future consideration

Spec Grid Record for Operators Upon Valve Placement in OpenPlant Modeler

In OpenPlant Modeler, we have only one option to place valve, meaning we dont have valve with Open and Closed type for its placement. As per standard, for open and closed type of valve we have different operator length. At present in OpenPlant Mod...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Validate tool/conversion report for AutoPlant to OpenPlant conversion

We need to get tool allows User to run validation for AutoPlant to OpenPlant conversion or to get something like report, where User will be able to see the conversion process report, like: what classes were converted, what is the status, what is m...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Ability to auto perform connectivity check

If Openplant can detect and connectivity error and display it as an error to the user, it should be able to automatically run connectivity check. At the very least, "Run Connectivity Check" should be added as a button to the disconnect error dialo...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Stage -Save should Update Associated properties aswell

OPPID -OPM plantSight integration 1.P&ID are synced to PlantSight successfully first time.If everything is properly defined then all pipelines are reflected into Browse option of OPM.After linking P&ID tags into OPM Modeled pipeline/compon...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Activate/Deactivate feature for reference files

OBD has Activate/Deactivate feature for reference files. This allows users to edit the reference files in the same session without switching to the reference model. Our mechanical team is currently using OBD for equipment modeling and they use thi...
about 2 years ago in OpenPlant Modeler 2 Future consideration

"Save-As" or "Copy/Rename" of a Model connected to PlantSight should change GUID

When using OpenPlant modeler with a project connected to PlantSight, you cannot perform a "Save as" or "Copy and rename". This is because when you do “Save As” or “Copy” on A.DGN to lets say B.DGN, the GUID of the model is not changed. Plantsight ...
over 2 years ago in OpenPlant Modeler 0 Future consideration