Pipe components properties into Itemtypes using Expressions
This is a feature we currently use in Prostructures to get Steel information into Item types via expressions such as this.GetElement.Length(). We would like to be able to do this with Piping components in OPM which would make our exports consisten...
Ability to assign null values to Long, Int, Double type properties in OPM Schemas
Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
Ensuring Custom information header in reference does not disappear when published to Imodel
Dear Project Admin, our custom project information header disappear whenever we publish to imodel. This information can be found in the nested reference files of our main container file. When we are giving to our client the main container model, t...
Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc.
Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc. Similar to end condition mappings End Condition Extend Type for valves.
9 months ago
in OpenPlant PID
0
Future consideration
LUG joints used widely for project use - This was readily available in v8i version but now it is not supported in CE. Logging on behalf of E365 user - Stantec Consulting - Australia
CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches
PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
Create an Advanced Query Function that can pull Class UOM
Create an ECSQL built-in function like ‘ec_clanname() and ‘ec_classid()’. It could have this form: ec_getPropertyUnit( ecclass, ecproperty ) Its functionality is to pull the component's unit of measurement (UOM).