Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 352

Validation of Component Dimensions

OPM users need a way to check dimensions of components against the pipespecs. We have had several instances where pipespec dimensions get updated by piping engineering after OPM Users have already routed in the model. OPM users currently have no w...
almost 3 years ago in OpenPlant Modeler 0 Future consideration

Tag Replication to display full tag

When using the tag replication tool, the main tag indicates replication by adding the number of replicated components in parenthesis. What we would like to see is for the replication tool to prompt the user to place each replicated tag annotation ...
almost 2 years ago in OpenPlant PID 0 Future consideration

True Beta Testing

I would really like to see a true beta testing program implemented for OpenPlant. I have logged 40+ product defects after upgrading to newer versions of OPM. I am still waiting on fixes from the past years, and my users are struggling with in prod...
7 months ago in OpenPlant Modeler 0 Future consideration

Ability to auto perform connectivity check

If Openplant can detect and connectivity error and display it as an error to the user, it should be able to automatically run connectivity check. At the very least, "Run Connectivity Check" should be added as a button to the disconnect error dialo...
3 months ago in OpenPlant Modeler 0 Future consideration

Assign location info from Architecture Room Space to BRCM equipment UDA.

It will be useful to get the location info (room/area name) from OBD-Architecture room spaces into BRCM equipment UDA via file reference with a command for a selection of equipment.
3 months ago in Bentley Raceway and Cable Management 0 Future consideration

Fix and Enhance the Details(Items) Dialog so it's usable.

Currently the Details (Items) dialog will show a list of what ever has been selected. Option to sort dialog, defaults back 'Item' when working on data past the first page of data, (scroll down past the first 20 lines say) When a number of items ar...
7 months ago in OpenPlant Modeler 1 Future consideration

Wafer Bolt - Two bolts in the spec with the same nominal diameter and BOLT_LEN but different Description, OPM picks the first spec entry.

OpenPlant Modeler’s working behavior is to pull the nearest bolt entry from spec with a lower BOLT_LEN compared to the calculated length if there’s no available bolt entry from spec with a BOLT_LEN that is either equal or greater than the calculat...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Pipes and Breaks VBA

We have found a VBA that add the finish illustration of piping, the VBA also has option for cutting the pipe. YouTube: https://www.youtube.com/shorts/U7oqHvl1eMY Communities: https://communities.bentley.com/products/programming/microstation_progra...
7 months ago in OpenPlant Modeler 2 Future consideration

Enhance Valve Placement to allow users to set the valve state, actuator, and end condition properties in the placement dialog

As a piping designer, I would like to be able to set the valve state, actuator, and end conditions in the placement dialog so that I can initially set what I need and don't have to change it later by modifying the property values. Proposed Solutio...
over 1 year ago in OpenPlant PID 0 Future consideration

Stretch Components Tool

Sometimes the drawing is generated unreadable.With this tool we can stretch the component to a readable space in the drawing.
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration