Workflow Change for Logging Enhancement to Aha if Ticket is Already Reported

It would be great to check the procedural workflow for logging item to Aha if client has already reported a case to Bentley. Client has reported a case to Bentley and based on investigation of support it should be considered as enhancement. In thi...
2 months ago in OpenPlant Modeler 2 Will not implement

Enable spec validation to update bolts and gaskets.

Spec validation tool allows mass model updates when specifications are updated. Often specs are in early design stages when modeling starts. When bolts or gaskets have updates, replacing these components as currently setup takes a significant amou...
7 months ago in OpenPlant Modeler 2 Future consideration

Ability to add the File Name to Piping Components

In a File Based CAD Environment, the File Name is used to identify systems and other details about a model. Currently, users need to add this data manually to different piping and equipment components. When a file name changes, we find that design...
12 months ago in OpenPlant Modeler 0 Future consideration

Ability to add/ edit conduit matrix after duct bank has been modelled.

Currently adding the conduit to an existing duct bank or already modelled duct bank is not possible. In projects it is very frequent to change the duct bank matrix which after modelling the duct bank. If after modelling new conduit is required to ...
3 months ago in Bentley Raceway and Cable Management 1 Planned

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
3 months ago in OpenPlant PID 0 Future consideration

Validate from Spec using user defined properties

When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
12 months ago in OpenPlant Modeler 1 Future consideration

Add Search for Orphaned Tags and Delete Them

Currently there is no way to see the orphaned tags, except when syncing drawings we get "found duplicates " dialog and cannot locate those tags in the PlantSight. Bentley CS has cloned the imodel few times but that didn't get rid of all orphaned t...
about 1 month ago in OpenPlant Engineering Data Manager 0 Future consideration

Ability to update properties on multiple components

CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
3 months ago in OpenPlant Modeler 0 Future consideration

BOLT LENGTH FROM SPEC + WAFER JOINTS

OPM has a config variable OPM_CALCULATE_BOLT_LENGTH which controls if the tool automatically calculates the required bolt length or uses the value from the Spec. We would like to use the values defined in our spec in all cases, except for Wafer ty...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Set a custom ACS in OPM and have it recognized by OPIM

Currently, OPIM does not recognize the custom ACS and only displays coordinates according to the default origin. However, it would be beneficial if we could set a custom ACS in OPM and have it recognized by OPIM. Related SR ticket: 7001541451
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration