Route Selection option for Raceway size tool.

BRCM Raceway size is a best tool to change the raceway catalog and size, but this tool do not provide us ability to select the raceway route.We need to manually select each raceway segments and then change the size. We should have three options af...
almost 5 years ago in Bentley Raceway and Cable Management 0 Future consideration

Update Reports to include Component Reference to PID Drawing

We would like to have the PID Drawing Number of where components are located in the following standard reports (like we already do with the process line list) so that it's easy to locate which drawings they are found in: Equipment Report Instrumen...
over 2 years ago in OpenPlant PID 0 Future consideration

See OpenBuilding properties in OpenPlant

Many user do not want to create i.dgn files to see OpenBuilding properties in OpenPlant. They want to attach reference dgn model and see properties of building model.
almost 5 years ago in OpenPlant Modeler 1 Already exists

Additional cable laying method related to cable size

A user like to use an additional cable laying method related to the cable size. That mean cable with a specified diameter shall be routed single layer and all cable smaller shall be routed multi layer, also the two laying methods shall be separate...
over 2 years ago in Bentley Raceway and Cable Management 0 Future consideration

Construction attribute in Element Templates

You can assign the Construction attribute in Element Templates but when the OPM objects are drawn, the Construction assignment isn't honored. You can manually select the Template in the object's properties, but it would be good if the Construction...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Update UI for Change Spec Tool

The current Change Spec tool UI doesn't allow users to easily compare the old components with the new components. Why doesn't the UI show both the old data on the left, and the new data on the right in a comparable table. See attached screenshot. ...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
over 2 years ago in OpenPlant PID 0 Future consideration

Would like a Progress Message displayed during PlantSight synchronization

Whenever you push drawing records to PlantSight, it will prompt you with the Difference Dialog. Once we click on Sync it took time to reflect the dialog for "Please enter comments" but during that phase (difference dialog to comment dialog) there ...
over 2 years ago in OpenPlant PID 0 Future consideration

Add a key-in to remove an Associated Item value (SYSTEM)

In some situations, I may wish to remove an associated item property (i.e. SYSTEM) from existing components and documents. For example, I may want to reuse existing documents for a new project that has a different tagging convention and doesn't ne...
over 2 years ago in OpenPlant PID 0 Future consideration

Place Existing Signal Page Connector include column for connected instrument line type

Place Existing Signal Page Connector should include a column for connected instrument line type. If there were multiple Signal Page Connectors available, it is currently impossible to distinguish between pneumatic, capillary, electrical, etc. Sinc...
over 2 years ago in OpenPlant PID 0 Future consideration