Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 361 of 361

See OpenBuilding properties in OpenPlant

Many user do not want to create i.dgn files to see OpenBuilding properties in OpenPlant. They want to attach reference dgn model and see properties of building model.
almost 4 years ago in OpenPlant Modeler 1 Already exists

Be able to create EHT (Electrical Heat Trace) Isometrics from OpenPlant

The drafters would make a copy of piping isometric line work, scale them to fit the EHT isometric title block, and then manually add the EHT layout/Power connection/RTD location. The EHT isometric may span across multiple piping isometrics and lin...
almost 2 years ago in OpenPlant Isometrics Manager 3 Future consideration

Icons for different type of Instruments

While selecting an instrument from the generic option in the piping galleries we get all the instruments listed and then we need to select the required one to place in the model, instead if we have icon for the instruments for example Level switch...
about 2 years ago in OpenPlant Modeler 0 Future consideration

We need 3-Way components under 45 Degrees. Control valves , valves and Fittings

Placing a 3 Way Valve with third Way under 45 Degrees should be possible . Same should be possible for 3-Way Fittings ( Y-Strainer). Example see attached pictures. Needed for different customers. They as well add valves directly to the third way, ...
about 4 years ago in OpenPlant PID 2 Planned

CTRL + S - Update Server Copy

In OPM V8i, CTRL + S was a shortcut for Update Server Copy, why was this is dropped in OPM CE?
about 2 years ago in OpenPlant Modeler 3 Will not implement

Specification Filter per discipline

Currently we have possibility to filter specification list from pipeline property like Service, Unit ... but this should work for all discipline HVAC, Support, Cable.As the spec folder is common for all discipline if we have dedicated spec for Hva...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Import Raceway ID from line in Raceway Generator

got a request from PPA Slovakia: In case there is a line (e.g. created in other CAD tools) possible to use as line to convert into raceway using the Raceway Generator it shall be possible as option to use the attached Raceway ID from this line and...
about 4 years ago in Bentley Raceway and Cable Management 5 Future consideration

Lock cable in cable drum calculation

Got a request from PPA Slovakia It will be useful to have a lock for cable to not change in drum calculation. The situation is maybe: cables are routed and calculated in drum calculation which drum shall be used now a number of cable must be chang...
about 4 years ago in Bentley Raceway and Cable Management 0 Future consideration

AUTOPLANT SCHEMA ISSUE

SrvReqNo:[7001545099]} AUTOPLANT SCHEMA ISSUE Currently, the iTwin platform uses Microstation Bridge to view EC data generated in OPM. However, the AutoPlant schema cause several properties to be corrupted and not visible. OPM service team has ins...
about 2 years ago in OpenPlant Modeler 2 Future consideration

Routing Auto Elbows with multiple elbows in spec

We have specifications where multiple end preparations exist for elbows with the same size. Typically we have butt welded and threaded elbows for the same size pipe depending on the service. When you have 2 different types of elbows for the same s...
about 2 years ago in OpenPlant Modeler 3 Already exists